{"id":436859,"date":"2024-10-20T07:56:25","date_gmt":"2024-10-20T07:56:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-63198-2775-2023-3\/"},"modified":"2024-10-26T14:58:07","modified_gmt":"2024-10-26T14:58:07","slug":"ieee-63198-2775-2023-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-63198-2775-2023-3\/","title":{"rendered":"IEEE 63198-2775-2023"},"content":{"rendered":"

New IEEE Standard – Active.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
7<\/td>\nFOREWORD <\/td>\n<\/tr>\n
9<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
13<\/td>\n4 General principles <\/td>\n<\/tr>\n
14<\/td>\n5 System architecture
5.1 Architecture model <\/td>\n<\/tr>\n
15<\/td>\nFigures
Figure\u00a01 \u2013 System architecture model of a smart hydroelectric power plant <\/td>\n<\/tr>\n
16<\/td>\n5.2 Logical architecture
5.2.1 Overview <\/td>\n<\/tr>\n
17<\/td>\nFigure\u00a02 \u2013 Typical system logic architecture of a smart hydroelectric power plant <\/td>\n<\/tr>\n
18<\/td>\n5.2.2 Description of levels and zones <\/td>\n<\/tr>\n
19<\/td>\n5.3 Information model <\/td>\n<\/tr>\n
20<\/td>\n5.4 Network structure
5.4.1 General
5.4.2 Network structure of plant level and group-of-plants level <\/td>\n<\/tr>\n
21<\/td>\nFigure\u00a03 \u2013 Typical physical structure of plant level and group-of-plants level of a smart hydroelectric power plant <\/td>\n<\/tr>\n
22<\/td>\n5.4.3 Network structure of unit level and process level <\/td>\n<\/tr>\n
23<\/td>\nFigure\u00a04 \u2013 Typical network structure schematic diagram of process level and unit level <\/td>\n<\/tr>\n
24<\/td>\n5.4.4 Variants for the network structure <\/td>\n<\/tr>\n
25<\/td>\nFigure\u00a05 \u2013 Recommended communication network structures (Variant A) <\/td>\n<\/tr>\n
26<\/td>\nFigure\u00a06 \u2013 Recommended communication network structures (Variant B) <\/td>\n<\/tr>\n
27<\/td>\nFigure\u00a07 \u2013 Recommended communication network structures (Variant C) <\/td>\n<\/tr>\n
28<\/td>\n5.4.5 Network configuration of retrofit engineering
Figure\u00a08 \u2013 Recommended communication network structures (Variant D) <\/td>\n<\/tr>\n
29<\/td>\n5.4.6 External communication interfaces
6 Basic support system
6.1 Overview
Figure\u00a09 \u2013 Example of external interfaces of a smart hydroelectric power plant <\/td>\n<\/tr>\n
30<\/td>\n6.2 Time synchronization system
6.3 Power supply system
6.4 CCTV system <\/td>\n<\/tr>\n
31<\/td>\n6.5 Firefighting system
6.6 Access control system
6.7 Large screen display system <\/td>\n<\/tr>\n
32<\/td>\n7 Smart transducer
7.1 Overview
7.2 General technical requirements <\/td>\n<\/tr>\n
33<\/td>\n7.3 Structure of smart transducers
Figure\u00a010 \u2013 Structure of smart transducers <\/td>\n<\/tr>\n
34<\/td>\nFigure\u00a011 \u2013 Adaption of conventional transducers <\/td>\n<\/tr>\n
35<\/td>\n8 Functional requirements of IEDs
8.1 Overview
8.2 General technical requirements <\/td>\n<\/tr>\n
36<\/td>\n8.3 Measurement and control
8.3.1 Data acquisition and control execution
8.3.2 Local control <\/td>\n<\/tr>\n
37<\/td>\n8.3.3 Synchronization
8.3.4 Governor <\/td>\n<\/tr>\n
38<\/td>\n8.3.5 Excitation
8.3.6 Speed measurement <\/td>\n<\/tr>\n
39<\/td>\n8.4 Monitoring
8.4.1 Unit online monitoring
8.4.2 Online monitoring of transmission and transformation equipment <\/td>\n<\/tr>\n
40<\/td>\n8.4.3 Hydrology telemetry
8.4.4 Meteorological information acquisition <\/td>\n<\/tr>\n
41<\/td>\n8.4.5 Dam safety monitoring
8.5 Protection
8.5.1 Overview
8.5.2 Electrical protection <\/td>\n<\/tr>\n
42<\/td>\n8.5.3 Mechanical protection <\/td>\n<\/tr>\n
43<\/td>\n9 Platform and intelligent application
9.1 General
9.2 Integrated control and management platform
9.2.1 General
9.2.2 Data management
Figure\u00a012 \u2013 Functional architecture of ICAMP <\/td>\n<\/tr>\n
45<\/td>\n9.2.3 Basic service <\/td>\n<\/tr>\n
48<\/td>\n9.2.4 Basic applications <\/td>\n<\/tr>\n
50<\/td>\n9.3 Intelligent applications
9.3.1 Hydroelectric power plant economic operation <\/td>\n<\/tr>\n
54<\/td>\n9.3.2 Decision support for Condition-Based Maintenance (CBM) <\/td>\n<\/tr>\n
56<\/td>\n9.3.3 Dam safety analysis and evaluation
9.3.4 Security and safety interaction <\/td>\n<\/tr>\n
57<\/td>\n9.3.5 Plant environment monitoring <\/td>\n<\/tr>\n
58<\/td>\n9.3.6 Intelligent patrol <\/td>\n<\/tr>\n
59<\/td>\n9.3.7 Operation and maintenance simulation <\/td>\n<\/tr>\n
60<\/td>\n9.3.8 Intelligent alarm <\/td>\n<\/tr>\n
61<\/td>\n9.3.9 Intelligent work sheet and operation sheet
9.3.10 Data analysis and trend forecast <\/td>\n<\/tr>\n
63<\/td>\n9.3.11 Emergency command support <\/td>\n<\/tr>\n
65<\/td>\n10 Cyber security
10.1 General
10.2 Network structure security <\/td>\n<\/tr>\n
66<\/td>\nFigure\u00a013 \u2013 Recommended network architecture <\/td>\n<\/tr>\n
67<\/td>\n10.3 Data and communication security <\/td>\n<\/tr>\n
68<\/td>\nFigure\u00a014 \u2013 Security categories, typical attacks, and countermeasures
Figure\u00a015 \u2013 Correlations between IEC\u00a062351 series and IEC TC57 profile standards <\/td>\n<\/tr>\n
69<\/td>\n10.4 Device and software security <\/td>\n<\/tr>\n
70<\/td>\n10.5 Access control
10.6 IT infrastructure comprehensive supervision and management <\/td>\n<\/tr>\n
71<\/td>\n10.7 Audit and modification
10.8 Emergency plan and response
10.9 Employee training and awareness
11 Commissioning, operation and maintenance
11.1 Commissioning
11.1.1 Overview <\/td>\n<\/tr>\n
72<\/td>\n11.1.2 Testing scene management
11.1.3 Testing strategy management
11.1.4 Automatic testing execution
11.1.5 Testing record management
11.2 Operation and maintenance
11.2.1 Remote diagnosis
11.2.2 Product maintenance <\/td>\n<\/tr>\n
73<\/td>\n11.2.3 Documents management
12 Implementation procedures of a smart hydroelectric power plant <\/td>\n<\/tr>\n
74<\/td>\nFigure\u00a016 \u2013 Typical implementation procedures of a smart hydroelectric power plant <\/td>\n<\/tr>\n
75<\/td>\nBibliography <\/td>\n<\/tr>\n
78<\/td>\nFran\u00e7ais
SOMMAIRE <\/td>\n<\/tr>\n
81<\/td>\nAVANT-PROPOS <\/td>\n<\/tr>\n
83<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
84<\/td>\n1 Domaine d’application
2 R\u00e9f\u00e9rences normatives
3 Termes et d\u00e9finitions <\/td>\n<\/tr>\n
88<\/td>\n4 Principes g\u00e9n\u00e9raux <\/td>\n<\/tr>\n
89<\/td>\n5 Architecture du syst\u00e8me
5.1 Mod\u00e8le d\u2019architecture <\/td>\n<\/tr>\n
90<\/td>\nFigures
Figure\u00a01 \u2013 Mod\u00e8le d\u2019architecture du syst\u00e8me d\u2019une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
91<\/td>\n5.2 Architecture logique
5.2.1 Vue d\u2019ensemble <\/td>\n<\/tr>\n
92<\/td>\nFigure\u00a02 \u2013 Architecture logique syst\u00e8me type d\u2019une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
93<\/td>\n5.2.2 Description des niveaux et des zones <\/td>\n<\/tr>\n
94<\/td>\n5.3 Mod\u00e8le d\u2019information <\/td>\n<\/tr>\n
95<\/td>\n5.4 Structure de r\u00e9seau
5.4.1 G\u00e9n\u00e9ralit\u00e9s
5.4.2 Structure de r\u00e9seau du niveau centrale et du niveau groupe de centrales <\/td>\n<\/tr>\n
96<\/td>\nFigure\u00a03 \u2013 Structure physique type du niveau centrale et du niveau groupe de centrales d’une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
97<\/td>\n5.4.3 Structure de r\u00e9seau du niveau groupe et du niveau proc\u00e9d\u00e9 <\/td>\n<\/tr>\n
98<\/td>\nFigure\u00a04 \u2013 Sch\u00e9ma type de la structure du r\u00e9seau au niveau proc\u00e9d\u00e9 et au niveau groupe <\/td>\n<\/tr>\n
99<\/td>\n5.4.4 Variantes pour la structure du r\u00e9seau <\/td>\n<\/tr>\n
100<\/td>\nFigure\u00a05 \u2013 Structures de r\u00e9seau de communication recommand\u00e9es (Variante\u00a0A) <\/td>\n<\/tr>\n
101<\/td>\nFigure\u00a06 \u2013 Structures de r\u00e9seau de communication recommand\u00e9es (Variante\u00a0B) <\/td>\n<\/tr>\n
102<\/td>\nFigure\u00a07 \u2013 Structures de r\u00e9seau de communication recommand\u00e9es (Variante\u00a0C) <\/td>\n<\/tr>\n
103<\/td>\n5.4.5 Configuration du r\u00e9seau en r\u00e9novation
Figure\u00a08 \u2013 Structures de r\u00e9seau de communication recommand\u00e9es (Variante\u00a0D) <\/td>\n<\/tr>\n
104<\/td>\n5.4.6 Interfaces de communication externes
Figure\u00a09 \u2013 Exemple d’interfaces externes d’une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
105<\/td>\n6 Syst\u00e8me de soutien de base
6.1 Vue d\u2019ensemble
6.2 Syst\u00e8me de synchronisation temporelle <\/td>\n<\/tr>\n
106<\/td>\n6.3 Syst\u00e8me d’alimentation \u00e9lectrique
6.4 Syst\u00e8me\u00a0CCTV
6.5 Syst\u00e8me de lutte contre l\u2019incendie <\/td>\n<\/tr>\n
107<\/td>\n6.6 Syst\u00e8me de contr\u00f4le d’acc\u00e8s
6.7 Syst\u00e8me d’affichage \u00e0 grand \u00e9cran <\/td>\n<\/tr>\n
108<\/td>\n7 Transducteur intelligent
7.1 Vue d\u2019ensemble
7.2 Exigences techniques g\u00e9n\u00e9rales <\/td>\n<\/tr>\n
109<\/td>\n7.3 Structure des transducteurs intelligents
Figure\u00a010 \u2013 Structure des transducteurs intelligents <\/td>\n<\/tr>\n
110<\/td>\nFigure\u00a011 \u2013 Adaptation des transducteurs conventionnels <\/td>\n<\/tr>\n
111<\/td>\n8 Exigences fonctionnelles applicables aux dispositifs \u00e9lectroniques intelligents (DEI)
8.1 Vue d\u2019ensemble
8.2 Exigences techniques g\u00e9n\u00e9rales <\/td>\n<\/tr>\n
112<\/td>\n8.3 Mesurage et commande
8.3.1 Acquisition des donn\u00e9es et ex\u00e9cution des commandes <\/td>\n<\/tr>\n
113<\/td>\n8.3.2 Commande locale
8.3.3 Synchronisation
8.3.4 R\u00e9gulateur turbine <\/td>\n<\/tr>\n
115<\/td>\n8.3.5 Excitation
8.3.6 Mesurage de la vitesse <\/td>\n<\/tr>\n
116<\/td>\n8.4 Surveillance
8.4.1 Surveillance en ligne du groupe <\/td>\n<\/tr>\n
117<\/td>\n8.4.2 Surveillance en ligne des \u00e9quipements de transmission et de transformation \u00e9lectrique
8.4.3 T\u00e9l\u00e9m\u00e9trie hydrologique <\/td>\n<\/tr>\n
118<\/td>\n8.4.4 Acquisition des informations m\u00e9t\u00e9orologiques
8.4.5 Surveillance de la s\u00e9curit\u00e9 des barrages
8.5 Protection
8.5.1 Vue d\u2019ensemble <\/td>\n<\/tr>\n
119<\/td>\n8.5.2 Protection \u00e9lectrique
8.5.3 Protection m\u00e9canique <\/td>\n<\/tr>\n
120<\/td>\n9 Plateforme et applications intelligentes
9.1 G\u00e9n\u00e9ralit\u00e9s <\/td>\n<\/tr>\n
121<\/td>\n9.2 Plateforme de conduite et de gestion int\u00e9gr\u00e9e
9.2.1 G\u00e9n\u00e9ralit\u00e9s
9.2.2 Gestion des donn\u00e9es
Figure\u00a012 \u2013 Architecture fonctionnelle de l\u2019ICAMP <\/td>\n<\/tr>\n
123<\/td>\n9.2.3 Service de base <\/td>\n<\/tr>\n
127<\/td>\n9.2.4 Applications de base <\/td>\n<\/tr>\n
129<\/td>\n9.3 Applications intelligentes
9.3.1 Exploitation \u00e9conomique d’une centrale hydro\u00e9lectrique <\/td>\n<\/tr>\n
134<\/td>\n9.3.2 Aide \u00e0 la d\u00e9cision pour la maintenance conditionnelle (CBM) <\/td>\n<\/tr>\n
136<\/td>\n9.3.3 Analyse et \u00e9valuation de la s\u00e9curit\u00e9 des barrages
9.3.4 Interaction entre s\u00e9curit\u00e9 et s\u00fbret\u00e9 <\/td>\n<\/tr>\n
137<\/td>\n9.3.5 Surveillance de l’environnement de la centrale <\/td>\n<\/tr>\n
138<\/td>\n9.3.6 Ronde intelligente <\/td>\n<\/tr>\n
139<\/td>\n9.3.7 Simulation d’exploitation et de maintenance <\/td>\n<\/tr>\n
140<\/td>\n9.3.8 Alarme intelligente <\/td>\n<\/tr>\n
141<\/td>\n9.3.9 Fiche de travail et fiche d\u2019exploitation intelligentes <\/td>\n<\/tr>\n
142<\/td>\n9.3.10 Analyse des donn\u00e9es et pr\u00e9vision des tendances <\/td>\n<\/tr>\n
144<\/td>\n9.3.11 Aide aux commandes d\u2019urgence <\/td>\n<\/tr>\n
146<\/td>\n10 Cybers\u00e9curit\u00e9
10.1 G\u00e9n\u00e9ralit\u00e9s <\/td>\n<\/tr>\n
147<\/td>\n10.2 S\u00e9curit\u00e9 de la structure de r\u00e9seau
Figure\u00a013 \u2013 Architecture r\u00e9seau recommand\u00e9e <\/td>\n<\/tr>\n
149<\/td>\n10.3 S\u00e9curit\u00e9 des donn\u00e9es et des communications <\/td>\n<\/tr>\n
150<\/td>\nFigure\u00a014 \u2013 Cat\u00e9gories de s\u00e9curit\u00e9, attaques types et contre-mesures
Figure\u00a015 \u2013 Corr\u00e9lations entre la s\u00e9rie IEC\u00a062351 et les normes de profilsdu CE\u00a057 de l\u2019IEC <\/td>\n<\/tr>\n
151<\/td>\n10.4 S\u00e9curit\u00e9 des dispositifs et des logiciels <\/td>\n<\/tr>\n
152<\/td>\n10.5 Contr\u00f4le d’acc\u00e8s
10.6 Surveillance et gestion compl\u00e8tes de l’infrastructure informatique <\/td>\n<\/tr>\n
153<\/td>\n10.7 Audit et modification
10.8 Plan et r\u00e9ponse d’urgence <\/td>\n<\/tr>\n
154<\/td>\n10.9 Formation et sensibilisation des employ\u00e9s
11 Mise en service, exploitation et maintenance
11.1 Mise en service
11.1.1 Vue d\u2019ensemble
11.1.2 Gestion des environnements d\u2019essai
11.1.3 Gestion de la strat\u00e9gie d\u2019essai <\/td>\n<\/tr>\n
155<\/td>\n11.1.4 Ex\u00e9cution des essais automatiques
11.1.5 Gestion des enregistrements d\u2019essai
11.2 Exploitation et maintenance
11.2.1 Diagnostic \u00e0 distance
11.2.2 Maintenance des produits
11.2.3 Gestion des documents <\/td>\n<\/tr>\n
156<\/td>\n12 Proc\u00e9dures de mise en \u0153uvre d’une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
157<\/td>\nFigure\u00a016 \u2013 Proc\u00e9dures types de mise en \u0153uvred’une centrale hydro\u00e9lectrique intelligente <\/td>\n<\/tr>\n
158<\/td>\nBibliographie <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEC\/IEEE International Technical Guidelines for Smart Hydroelectric Power Plant (Published)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2023<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":436865,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-436859","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/436859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/436865"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=436859"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=436859"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=436859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}