{"id":439817,"date":"2024-10-20T08:11:18","date_gmt":"2024-10-20T08:11:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-59-2024\/"},"modified":"2024-10-26T15:19:18","modified_gmt":"2024-10-26T15:19:18","slug":"nfpa-59-2024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-59-2024\/","title":{"rendered":"NFPA 59 2024"},"content":{"rendered":"

Fire, explosions, and other related dangers pose significant risks to utility gas plants with liquefied petroleum gas systems. NFPA 59, Utility LP-Gas Plant Code, works in combination with DOT regulations to provide provisions for constructing and maintaining plants that store and vaporize LP-Gas or LP-Gas<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nBlank Page <\/td>\n<\/tr>\n
3<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
4<\/td>\nAdditional Important Notices and Disclaimers <\/td>\n<\/tr>\n
10<\/td>\nChapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Nonapplication of Code.
1.4 Retroactivity.
1.5 Equivalency.
1.6 Enforcement. <\/td>\n<\/tr>\n
11<\/td>\n1.7 Pressure Measurement.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications. <\/td>\n<\/tr>\n
12<\/td>\n2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions. <\/td>\n<\/tr>\n
14<\/td>\nChapter 4 General Requirements
4.1 Personnel Training.
4.2 Odorizing Gases.
4.3 Acceptance of Equipment.
4.4 Damage from Vehicles.
4.5 Ignition Source Control. <\/td>\n<\/tr>\n
16<\/td>\n4.6 Lighting.
4.7 Construction and Modification Records.
4.8 Design and Installation. <\/td>\n<\/tr>\n
17<\/td>\n4.9 Atmospheric Corrosion Control.
4.10 External Corrosion Control: Buried or Submerged Components.
4.11 Internal Corrosion Control.
4.12 Interference Currents. <\/td>\n<\/tr>\n
18<\/td>\nChapter 5 Nonrefrigerated Containers
5.1 Provision for Construction and Original Test of Nonrefrigerated Containers.
5.2 Design Pressure and Classification of Nonrefrigerated Containers.
5.3 ASME Container Markings.
5.4 Location of Nonrefrigerated Containers. <\/td>\n<\/tr>\n
19<\/td>\n5.5 Installation of Nonrefrigerated Storage Containers. <\/td>\n<\/tr>\n
20<\/td>\n5.6 Reinstallation of Nonrefrigerated Containers.
5.7 Filling Densities. <\/td>\n<\/tr>\n
21<\/td>\n5.8 Point of Transfer Spacing.
Chapter 6 Refrigerated Containers
6.1 Scope.
6.2 Refrigerated Containers Designed to Operate Below 7\u00a0psi (103\u00a0kPa) and Above 5000 bbls (800\u00a0m3). <\/td>\n<\/tr>\n
24<\/td>\n6.3 Refrigerated Containers Designed to Operate Above 15\u00a0psi (103\u00a0kPa). <\/td>\n<\/tr>\n
26<\/td>\nChapter 7 Piping, Valves, Process Pressure Vessels, and Equipment
7.1 General. <\/td>\n<\/tr>\n
27<\/td>\n7.2 Container Valves and Accessories. <\/td>\n<\/tr>\n
28<\/td>\n7.3 Filler and Discharge Pipes and Manifolds.
7.4 Liquid Level Gauging Device.
7.5 Hose Specifications for Nonrefrigerated LP-Gas.
7.6 Drips, Pits, and Drains. <\/td>\n<\/tr>\n
29<\/td>\n7.7 Pumps and Compressors.
7.8 Pumps and Compressors in Refrigerated LP-Gas Systems.
7.9 Process Pressure Vessels.
7.10 Protection of Container Accessories.
7.11 Transfer Equipment. <\/td>\n<\/tr>\n
30<\/td>\nChapter 8 Buildings or Structures Housing LP-Gas Distribution Facilities
8.1 Scope.
8.2 Separate Structures or Buildings.
8.3 Attached Structures or Rooms Within Structures. <\/td>\n<\/tr>\n
31<\/td>\n8.4 Rooms Housing Vaporizers or Mixers.
Chapter 9 Vaporizers, Heat Exchangers, and Gas\u2013Air Mixers
9.1 General.
9.2 Buildings or Rooms Housing Vaporizers or Gas\u2013Air Mixers.
9.3 Vaporizers.
9.4 Gas\u2013Air Mixers. <\/td>\n<\/tr>\n
32<\/td>\n9.5 Vaporizer Installation. <\/td>\n<\/tr>\n
33<\/td>\nChapter 10 Relief Devices
10.1 General.
10.2 Nonrefrigerated Container Relief Devices. <\/td>\n<\/tr>\n
35<\/td>\n10.3 Refrigerated Container Relief Devices.
10.4 Relief Device Sizing for Refrigerated Containers.
10.5 Refrigerated Container Relief Device Sizing for Fire Exposure. <\/td>\n<\/tr>\n
36<\/td>\n10.6 Pressure Relief Valve Discharge Vents.
10.7 Vaporizers. <\/td>\n<\/tr>\n
37<\/td>\n10.8 Hydrostatic Relief Valves.
Chapter 11 Operations
11.1 General.
11.2 Operating Procedures Manuals.
11.3 Handling.
11.4 Operating Records. <\/td>\n<\/tr>\n
38<\/td>\nChapter 12 Maintenance
12.1 Retroactivity.
12.2 Maintenance Manuals.
12.3 Corrosion Protection. <\/td>\n<\/tr>\n
39<\/td>\n12.4 Maintenance of Emergency Shutoff and Check Valves.
12.5 Maintenance of Foundations and Supports.
12.6 Maintenance of Fire Protection Equipment.
12.7 Leakage Surveys.
12.8 Auxiliary Power Sources.
12.9 Purging Prior to Maintenance.
12.10 Maintenance Records. <\/td>\n<\/tr>\n
40<\/td>\nChapter 13 Fire Protection, Safety, and Security
13.1 General.
13.2 Gas, Fire, and Leak Detection. <\/td>\n<\/tr>\n
41<\/td>\n13.3 Container Protection.
13.4 Fire Protection Water Systems.
13.5 Fire-Extinguishing and Other Fire Protection Equipment.
13.6 Special Protection.
13.7 Maintenance of Fire Protection Equipment.
13.8 Personnel Safety. <\/td>\n<\/tr>\n
42<\/td>\n13.9 Security.
Annex A Explanatory Material <\/td>\n<\/tr>\n
47<\/td>\nAnnex B Method of Calculating Maximum Liquid Volume That Can Be Placed in a Container at Any Liquid Temperature <\/td>\n<\/tr>\n
49<\/td>\nAnnex C Method of Calculating Maximum Volume of Liquefied Petroleum Gas That Can Be Placed in a Container for Which Length of Fixed Drip Tube Is Set <\/td>\n<\/tr>\n
50<\/td>\nAnnex D Relief Device Sizing
Annex E Sample Ordinance Adopting NFPA\u00a059 <\/td>\n<\/tr>\n
51<\/td>\nAnnex F Informational References <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 59:Utility LP-Gas Plant Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2024<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":439821,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-439817","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/439817","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/439821"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=439817"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=439817"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=439817"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}