Non-destructive testing. Acoustic emission testing. Equipment characterisation – Verification of operating characteristics
Published By | Publication Date | Number of Pages |
BSI | 2021 | 82 |
This document specifies test routines for the periodic verification of the performance of acoustic emission (AE) test equipment, i.e. sensors, pre-amplifiers, signal processors, external parametric inputs.
It is intended for use by qualified personnel to implement an automated verification process.
Verification of the measurement characteristics is advised after purchase of equipment, in order to obtain reference data for later verifications. Verification is also advised after repair, modifications, use under extraordinary conditions, or if one suspects a malfunction.
The procedures specified in this document do not exclude other qualified methods, e.g. verification in the frequency domain. These procedures apply in general unless the manufacturer specifies alternative equivalent procedures.
Safety aspects of equipment for use in potentially explosive zones are not considered in this document.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Required test equipment and test signals 4.1 List of required equipment |
11 | 4.2 Test signal waveforms 4.2.1 Continuous sine wave |
12 | 4.2.2 Triangular-modulated sine wave burst signal |
14 | 4.2.3 Sin2-modulated sine wave burst signal |
15 | 4.2.4 Rectangular-modulated sine wave burst signal |
16 | 4.2.5 Rectangular pulse 4.2.6 Repetitive signals |
17 | 4.2.7 DC signal 4.2.8 Summary of test signals 4.3 Test block 4.4 Shielding test plate 5 Sensor verification 5.1 General |
18 | 5.2 Intended purpose 5.3 Preparation of the report form and preliminary examination |
19 | 5.4 Sensitivity verification 5.4.1 General 5.4.2 Test procedure |
20 | 5.5 Verification of the electrical shield crosstalk 5.5.1 General |
24 | 5.5.2 Procedure 5.6 Pre-amplifier verification of sensor-internal pre-amplifier |
25 | 6 Pre-amplifier verification 6.1 Preparation of the report form and preliminary examination |
26 | 6.2 Verification of DC consumption 6.2.1 General |
27 | 6.2.2 Verifying a limit or a deviation 6.2.3 Procedure |
28 | 6.3 Verification of the pre-amplifier characteristics 6.3.1 General 6.3.2 Gain verification 6.3.2.1 General |
29 | 6.3.2.2 Test procedure |
30 | 6.3.3 Bandwidth verification 6.3.3.1 General |
31 | 6.3.3.2 Report preparation 6.3.3.3 Test procedure |
32 | 6.3.4 Electronic noise verification 6.3.4.1 General |
33 | 6.3.4.2 Setup for noise measurement |
34 | 6.3.4.3 Test procedure 6.3.5 Dynamic range verification 6.3.5.1 General |
36 | 6.3.5.2 Procedure |
37 | 6.3.6 Common mode rejection verification 6.3.7 Pulsing test 7 Acoustic emission signal processor verification 7.1 General 7.1.1 Overview |
40 | 7.1.2 Preparation of the report form |
41 | 7.2 Signal processor noise verification 7.2.1 General |
42 | 7.2.2 Test procedure |
43 | 7.3 Verification of RMS measurement and floating threshold functionality 7.3.1 General |
45 | 7.3.2 Test procedure 7.4 Verification of the fixed detection threshold 7.4.1 General |
47 | 7.4.2 Procedure for signal stimulation and data acquisition 7.4.3 Procedure for the data verification 7.5 Bandwidth and filter roll-off verification 7.5.1 General |
48 | 7.5.2 Data needed for verification of bandwidth and roll-off verification 7.5.3 Procedure for signal stimulation and storage 7.5.4 Test procedure for bandwidth verification based on stored AE data |
49 | 7.6 Burst signal parameter verification 7.6.1 General 7.6.2 Maximum amplitude verification 7.6.2.1 Applying the acceptance criteria |
50 | 7.6.2.2 Setpoint for the arbitrary function generator (AFG) amplitude |
51 | 7.6.2.3 Test procedure for signal stimulation and data acquisition |
52 | 7.6.2.4 Maximum amplitude data verification procedure 7.6.3 Duration verification 7.6.3.1 General |
53 | 7.6.3.2 Signal stimulation and measurement procedure for duration verification 7.6.3.3 Test procedure for duration data verification |
54 | 7.6.4 Rise-time verification 7.6.4.1 General |
55 | 7.6.4.2 Test procedure for signal stimulation and measurement for rise-time verification 7.6.4.3 Data analysis procedure for rise-time verification |
56 | 7.6.5 Ring-down count verification |
57 | 7.6.6 Energy and signal strength verification 7.6.6.1 General 7.6.6.2 Maximum amplitude-varied energy and signal strength verification |
59 | 7.6.6.3 Duration-varied energy and signal strength verification |
60 | 8 Verification of the system performance 8.1 External parametric input verification 8.1.1 General |
61 | 8.1.2 Formulae for parametric input verification |
62 | 8.1.3 Avoiding the use of a high-accuracy digital voltmeter (HADVM) 8.1.4 Report form preparation |
63 | 8.1.5 Test procedure for signal stimulation and measurement for parametric input verification |
64 | 8.1.6 Test procedure for parametric input data verification 8.2 Pulser verification 8.3 System acquisition rate verification |
65 | 8.4 Delta t (Δt) measurement verification 8.5 Software verification |
66 | 9 Test report |
67 | Annex A (informative)Report form for the sensor performance verification |
69 | Annex B (informative)Report form for the pre-amplifier performance verification |
72 | Annex C (informative)Report form for the acoustic emission signal processor verification |
77 | Annex D (informative)Report form for the external parametric input verification |
79 | Annex E (informative)List of designations |