NY StateResidentialCode 2020 TEMP
$83.96
Residential Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2020 |
This is a fully integrated custom code based on the 2018 International Residential Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | Copyright |
3 | ACKNOWLEDGEMENTS |
5 | PREFACE |
7 | EFFECTIVE USE |
17 | TABLE OF CONTENTS |
24 | APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY |
25 | Part I—Administrative CHAPTER 1 SCOPE AND ADMINISTRATION Section R101 Title, Scope and Purpose |
26 | R102 Applicability |
27 | R103 Administration and Enforcement |
28 | R104 Materials, Equipment and Methods of Construction R105 Building Permits, Construction Inspections, Stop Work Orders, and Certificates of Occupancy |
30 | R106 Submitted Documents |
31 | R107 Service Utilities R108 Inspection of Solid Fuel-Burning Heating Appliances, Chimneys and Flues |
33 | Part II—Definitions CHAPTER 2 DEFINITIONS Section R201 General R202 Definitions |
51 | Part III—Building Planning and Construction CHAPTER 3 BUILDING PLANNING Section R301 Design Criteria |
71 | R302 Fire-resistant Construction |
76 | R303 Light, Ventilation and Heating |
78 | R304 Minimum Room Areas R305 Ceiling Height R306 Sanitation R307 Toilet, Bath and Shower Spaces R308 Glazing |
82 | R309 Garages and Carports |
83 | R310 Emergency Escape and Rescue Openings |
84 | R311 Means of Egress |
88 | R312 Guards and Window Fall Protection R313 Automatic Fire Sprinkler Systems |
89 | R314 Smoke Alarms and Heat Detection |
90 | R315 Carbon Monoxide Alarms R316 Foam Plastic |
92 | R317 Protection of Wood and Wood-based Products against Decay |
93 | R318 Protection against Subterranean Termites |
94 | R319 Site Address R320 Accessibility R321 Elevators and Platform Lifts R322 Flood-resistant Construction |
98 | R323 Storm Shelters R324 Solar Energy Systems |
99 | R325 Mezzanines |
100 | R326 Swimming Pools, Spas and Hot Tubs |
103 | R327 Energy Storage Systems |
105 | CHAPTER 4 FOUNDATIONS Section R401 General R402 Materials |
106 | R403 Footings |
123 | R404 Foundation and Retaining Walls |
143 | R405 Foundation Drainage |
144 | R406 Foundation Waterproofing and Dampproofing |
145 | R407 Columns R408 Under-floor Space |
147 | CHAPTER 5 FLOORS Section R501 General R502 Wood Floor Framing |
156 | R503 Floor Sheathing |
158 | R504 Pressure Preservative-treated Wood Floors (On Ground R505 Cold-formed Steel Floor Framing |
173 | R506 Concrete Floors (On Ground R507 Exterior Decks |
185 | CHAPTER 6 WALL CONSTRUCTION Section R601 General R602 Wood Wall Framing |
235 | R603 Cold-formed Steel Wall Framing |
271 | R604 Wood Structural Panels R605 Particleboard R606 General Masonry Construction |
288 | R607 Glass Unit Masonry R608 Exterior Concrete Wall Construction |
359 | R609 Exterior Windows and Doors |
363 | R610 Structural Insulated Panel Wall Construction |
373 | CHAPTER 7 WALL COVERING Section R701 General R702 Interior Covering |
378 | R703 Exterior Covering |
397 | CHAPTER 8 ROOF-CEILING CONSTRUCTION Section R801 General R802 Wood Roof Framing |
423 | R803 Roof Sheathing |
426 | R804 Cold-formed Steel Roof Framing |
444 | R805 Ceiling Finishes R806 Roof Ventilation |
445 | R807 Attic Access |
447 | CHAPTER 9 ROOF ASSEMBLIES Section R901 General R902 Fire Classification R903 Weather Protection |
448 | R904 Materials R905 Requirements for Roof Coverings |
460 | R906 Roof Insulation R907 Rooftop-mounted Photovoltaic Panel Systems |
461 | R908 Reroofing |
463 | CHAPTER 10 CHIMNEYS AND FIREPLACES Section R1001 Masonry Fireplaces |
467 | R1002 Masonry Heaters R1003 Masonry Chimneys |
471 | R1004 Factory-built Fireplaces |
472 | R1005 Factory-built Chimneys R1006 Exterior Air Supply |
475 | Part IV—Energy Conservation CHAPTER 11 ENERGY EFFICIENCY Section N1101 General |
481 | N1102 Building Thermal Envelope |
488 | N1103 Systems |
491 | N1104 Electrical Power and Lighting Systems (Mandatory N1105 Simulated Performance Alternative (Performance |
492 | N1106 Energy Rating Index Compliance Alternative |
496 | N1107 Existing Buildings—General |
497 | N1108 Additions N1109 Alterations |
498 | N1110 Repairs N1111 Change of Occupancy or Use |
499 | Part V—Mechanical CHAPTER 12 MECHANICAL ADMINISTRATION Section M1201 General M1202 Existing Mechanical Systems |
501 | CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS Section M1301 General M1302 Approval M1303 Labeling of Appliances M1304 Type of Fuel M1305 Appliance Access |
502 | M1306 Clearances from Combustible Construction |
503 | M1307 Appliance Installation |
506 | M1308 Mechanical Systems Installation |
507 | CHAPTER 14 HEATING AND COOLING EQUIPMENT AND APPLIANCES Section M1401 General M1402 Central Furnaces M1403 Heat Pump Equipment M1404 Refrigeration Cooling Equipment M1405 Baseboard Convectors M1406 Radiant Heating Systems |
508 | M1407 Duct Heaters M1408 Vented Floor Furnaces |
509 | M1409 Vented Wall Furnaces M1410 Vented Room Heaters M1411 Heating and Cooling Equipment |
510 | M1412 Absorption Cooling Equipment M1413 Evaporative Cooling Equipment |
511 | M1414 Fireplace Stoves M1415 Masonry Heaters M1416 Portable Kerosene Heaters |
513 | CHAPTER 15 EXHAUST SYSTEMS Section M1501 General M1502 Clothes Dryer Exhaust |
514 | M1503 Domestic Cooking Exhaust Equipment |
515 | M1504 Exhaust Ducts and Exhaust Openings M1505 Mechanical Ventilation |
517 | CHAPTER 16 DUCT SYSTEMS Section M1601 Duct Construction |
520 | M1602 Return Air |
521 | CHAPTER 17 COMBUSTION AIR Section M1701 General |
523 | CHAPTER 18 CHIMNEYS AND VENTS Section M1801 General M1802 Vent Components |
524 | M1803 Chimney and Vent Connectors |
525 | M1804 Vents M1805 Masonry and Factory-built Chimneys |
527 | CHAPTER 19 SPECIAL APPLIANCES, EQUIPMENT AND SYSTEMS Section M1901 Ranges and Ovens M1902 Sauna Heaters M1903 Stationary Fuel Cell Power Plants M1904 Gaseous Hydrogen Systems |
529 | CHAPTER 20 BOILERS AND WATER HEATERS Section M2001 Boilers M2002 Operating and Safety Controls M2003 Expansion Tanks |
530 | M2004 Water Heaters Used for Space Heating M2005 Water Heaters M2006 Pool Heaters |
531 | CHAPTER 21 HYDRONIC PIPING Section M2101 Hydronic Piping Systems Installation M2102 Baseboard Convectors |
533 | M2103 Floor Heating Systems M2104 Low Temperature Piping M2105 Ground-Source Heat-Pump System Loop Piping |
537 | CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS Section M2201 Oil Tanks M2202 Oil Piping, Fitting and Connections M2203 Installation |
538 | M2204 Oil Pumps and Valves |
539 | CHAPTER 23 SOLAR THERMAL ENERGY SYSTEMS Section M2301 Solar Thermal Energy Systems |
541 | Part VI—Fuel Gas CHAPTER 24 FUEL GAS Section G2401 General G2402 General G2403 General Definitions |
547 | G2404 General |
548 | G2405 Structural Safety G2406 Appliance Location |
549 | G2407 Combustion, Ventilation and Dilution Air |
553 | G2408 Installation G2409 Clearance Reduction |
555 | G2410 Electrical G2411 Electrical Bonding |
557 | G2412 General |
558 | G2413 Pipe Sizing |
559 | G2414 Piping Materials |
582 | G2415 Piping System Installation |
584 | G2416 Piping Bends and Changes in Direction |
585 | G2417 Inspection, Testing and Purging |
587 | G2418 Piping Support G2419 Drips and Sloped Piping |
588 | G2420 Shutoff Valves G2421 Flow Controls |
589 | G2422 Appliance Connections |
590 | G2423 Compressed Natural Gas Motor Vehicle Fuel-dispensing Facilities G2424 Piping Support Intervals G2425 General |
592 | G2426 Vents G2427 Venting of Appliances |
601 | G2428 Sizing of Category I Appliance Venting Systems |
613 | G2429 Direct-vent, Integral Vent, Mechanical Vent and Ventilation/Exhaust Hood Venting G2430 Factory-built Chimneys G2431 General G2432 Decorative Appliances for Installation in Fireplaces G2433 Log Lighters G2434 Vented Gas Fireplaces (Decorative Appliances G2435 Vented Gas Fireplace Heaters G2436 Vented Wall Furnaces |
614 | G2437 Floor Furnaces G2438 Clothes Dryers G2439 Clothes Dryer Exhaust |
615 | G2440 Sauna Heaters |
616 | G2441 Pool and Spa Heaters G2442 Forced-air Warm-air Furnaces |
617 | G2443 Conversion Burners G2444 Unit Heaters G2445 Unvented Room Heaters G2446 Vented Room Heaters |
618 | G2447 Cooking Appliances G2448 Water Heaters G2449 Air-conditioning Appliances G2450 Illuminating Appliances |
619 | G2451 Infrared Radiant Heaters G2452 Boilers G2453 Chimney Damper Opening Area G2454 Outdoor Decorative Appliances |
621 | Part VII—Plumbing CHAPTER 25 PLUMBING ADMINISTRATION Section P2501 General P2502 Existing Plumbing Systems P2503 Inspection and Tests |
623 | CHAPTER 26 GENERAL PLUMBING REQUIREMENTS Section P2601 General P2602 Individual Water Supply and Sewage Disposal P2603 Structural and Piping Protection |
624 | P2604 Trenching and Backfilling P2605 Support P2606 Penetrations |
625 | P2607 Waterproofing of Openings P2608 Workmanship P2609 Materials Evaluation and Listing |
627 | CHAPTER 27 PLUMBING FIXTURES Section P2701 Fixtures, Faucets and Fixture Fittings P2702 Fixture Accessories P2703 Tail Pieces P2704 Slip-joint Connections P2705 Installation P2706 Waste Receptors |
629 | P2707 Directional Fittings P2708 Showers P2709 Shower Receptors |
630 | P2710 Shower Walls P2711 Lavatories P2712 Water Closets |
631 | P2713 Bathtubs P2714 Sinks P2715 Laundry Tubs P2716 Food-waste Disposer P2717 Dishwashing Machines P2718 Clothes Washing Machine P2719 Floor Drains P2720 Whirlpool Bathtubs P2721 Bidet Installations |
632 | P2722 Fixture Fitting P2723 Macerating Toilet Systems P2724 Specialty Temperature Control Devices and Valves P2725 Nonliquid Saturated Treatment Systems |
633 | CHAPTER 28 WATER HEATERS Section P2801 General P2802 Solar Water Heating Systems P2803 Water Heaters Used for Space Heating |
634 | P2804 Relief Valves |
635 | CHAPTER 29 WATER SUPPLY AND DISTRIBUTION Section P2901 General P2902 Protection of Potable Water Supply |
638 | P2903 Water Supply System |
643 | P2904 Dwelling Unit Fire Sprinkler Systems |
647 | P2905 Heated Water Distribution Systems P2906 Materials, Joints and Connections |
659 | P2907 Changes in Direction P2908 Support P2909 Drinking Water Treatment Units P2910 Nonpotable Water Systems |
662 | P2911 On-site Nonpotable Water Reuse Systems |
663 | P2912 Nonpotable Rainwater Collection and Distribution Systems |
665 | P2913 Reclaimed Water Systems |
667 | CHAPTER 30 SANITARY DRAINAGE Section P3001 General P3002 Materials |
669 | P3003 Joints and Connections |
671 | P3004 Determining Drainage Fixture Units P3005 Drainage System |
675 | P3006 Sizing of Drain Pipe Offsets P3007 Sumps and Ejectors |
676 | P3008 Backwater Valves P3009 Subsurface Landscape Irrigation Systems |
678 | P3010 Replacement of Underground Building Sewers and Building Drains by Pipe Bursting Methods |
679 | P3011 Replacement of Underground Sewers by PVC Fold and Form Methods |
681 | CHAPTER 31 VENTS Section P3101 Vent Systems P3102 Vent Stacks and Stack Vents P3103 Vent Terminals |
682 | P3104 Vent Connections and Grades P3105 Fixture Vents P3106 Individual Vent P3107 Common Vent |
683 | P3108 Wet Venting P3109 Waste Stack Vent P3110 Circuit Venting |
684 | P3111 Combination Waste and Vent System P3112 Island Fixture Venting P3113 Vent Pipe Sizing |
685 | P3114 Air Admittance Valves |
687 | CHAPTER 32 TRAPS Section P3201 Fixture Traps |
689 | CHAPTER 33 STORM DRAINAGE Section P3301 General P3302 Subsoil Drains P3303 Sumps and Pumping Systems |
691 | Part VIII—Electrical CHAPTER 34 GENERAL REQUIREMENTS Section E3401 General |
692 | E3402 Building Structure Protection E3403 Inspection and Approval E3404 General Equipment Requirements |
694 | E3405 Equipment Location and Clearances E3406 Electrical Conductors and Connections |
697 | E3407 Conductor and Terminal Identification |
699 | CHAPTER 35 ELECTRICAL DEFINITIONS Section E3501 General |
705 | CHAPTER 36 SERVICES Section E3601 General Services E3602 Service Size and Rating |
706 | E3603 Service, Feeder and Grounding Electrode Conductor Sizing |
707 | E3604 Overhead Service and Service-entrance Conductor Installation |
709 | E3605 Service-entrance Conductors |
710 | E3606 Service Equipment—General E3607 System Grounding |
711 | E3608 Grounding Electrode System |
712 | E3609 Bonding |
714 | E3610 Grounding Electrode Conductors E3611 Grounding Electrode Conductor Connection to the Grounding Electrodes |
717 | CHAPTER 37 BRANCH CIRCUIT AND FEEDER REQUIREMENTS Section E3701 General E3702 Branch Circuit Ratings |
718 | E3703 Required Branch Circuits |
719 | E3704 Feeder Requirements |
720 | E3705 Conductor Sizing and Overcurrent Protection |
723 | E3706 Panelboards |
725 | CHAPTER 38 WIRING METHODS Section E3801 General Requirements E3802 Above-ground Installation Requirements |
727 | E3803 Underground Installation Requirements |
731 | CHAPTER 39 POWER AND LIGHTING DISTRIBUTION Section E3901 Receptacle Outlets |
733 | E3902 Ground-fault and Arc-fault Circuit-interrupter Protection |
735 | E3903 Lighting Outlets E3904 General Installation Requirements |
736 | E3905 Boxes, Conduit Bodies and Fittings |
750 | E3906 Installation of Boxes, Conduit Bodies and Fittings |
752 | E3907 Cabinets and Panelboards |
754 | E3908 Grounding |
758 | E3909 Flexible Cords |
759 | CHAPTER 40 DEVICES AND LUMINAIRES Section E4001 Switches |
760 | E4002 Receptacles |
762 | E4003 Luminaires |
763 | E4004 Luminaire Installation |
764 | E4005 Track Lighting |
765 | CHAPTER 41 APPLIANCE INSTALLATION Section E4101 General |
769 | CHAPTER 42 SWIMMING POOLS Section E4201 General E4202 Wiring Methods for Pools, Spas, Hot Tubs and Hydromassage Bathtubs |
771 | E4203 Equipment Location and Clearances |
773 | E4204 Bonding |
775 | E4205 Grounding |
776 | E4206 Equipment Installation |
779 | E4207 Storable Swimming Pools, Storable Spas, and Storable Hot Tubs E4208 Spas and Hot Tubs |
780 | E4209 Hydromassage Bathtubs |
781 | CHAPTER 43 CLASS 2 REMOTE-CONTROL, SIGNALING AND POWERLIMITED CIRCUITS Section E4301 General E4302 Power Sources E4303 Wiring Methods |
782 | E4304 Installation Requirements |
783 | Part IX—Referenced Standards CHAPTER 44 REFERENCED STANDARDS |
821 | APPENDIX A SIZING AND CAPACITIES OF GAS PIPING |
833 | APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS |
843 | APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS |
845 | APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION |
851 | APPENDIX E MANUFACTURED HOUSING USED AS DWELLINGS Section AE101 Scope AE102 Application to Existing Manufactured Homes and Building Service Equipment |
852 | AE103 Permits and Inspections AE201 Definitions AE301 Occupancy Classification |
853 | AE302 Location on Property AE401 Design AE402 Foundation Systems |
854 | AE403 Skirting and Perimeter Enclosures AE404 Building Service Equipment AE405 Exits AE406 Occupancy, Fire Safety and Energy Conservation Standards |
855 | APPENDIX F RADON CONTROL METHODS Section AF101 Scope AF102 Definitions AF103 Requirements |
863 | APPENDIX G PIPING STANDARDS FOR VARIOUS APPLICATIONS Section AG101 Plastic Piping Standards |
867 | AG102 Referenced Standards |
869 | APPENDIX H PATIO COVERS Section AH101 General AH102 Definition AH103 Exterior Walls and Openings AH104 Height AH105 Structural Provisions AH106 Special Provisions for Aluminum Screen Enclosures in Hurricane-prone Regions |
873 | APPENDIX I RESERVED |
875 | APPENDIX J EXISTING BUILDINGS AND STRUCTURES Section AJ101 Purpose and Intent AJ102 Compliance |
876 | AJ103 Applicability AJ104 Energy Efficiency AJ105 Preliminary Meeting AJ106 Evaluation of an Existing Building AJ201 Definitions |
878 | AJ301 Classification of Work AJ401 Repairs |
880 | AJ501 Alterations—Level 1 |
881 | AJ601 Alterations—Level 2 |
883 | AJ701 Change of Occupancy |
884 | AJ702 Bed and Breakfast Dwellings AJ801 Additions |
886 | AJ901 Historic Buildings |
887 | AJ1001 Relocated or Moved Buildings |
888 | AJ1101Replacement |
889 | APPENDIX K SOUND TRANSMISSION Section AK101 General AK102 Airborne Sound AK103 Structural-borne Sound AK104 Referenced Standards |
891 | APPENDIX L RESERVED |
893 | APPENDIX M RESERVED |
895 | APPENDIX N VENTING METHODS |
901 | APPENDIX O AUTOMATIC VEHICULAR GATES Section AO101 General AO102 Definition AO103 Automatic Vehicular Gates AO104 Referenced Standards |
903 | APPENDIX P SIZING OF WATER PIPING SYSTEM Section AP101 General AP102 Information Required AP103 Selection of Pipe Size |
920 | AP201 Selection of Pipe Size |
923 | APPENDIX Q TINY HOUSES Section AQ101 General AQ102 Definitions AQ103 Ceiling Height AQ104 Lofts |
924 | AQ105 Emergency Escape and Rescue Openings |
925 | APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION Section AR101 General AR102 Definitions AR103 Nonbearing Light Straw- Clay Construction |
928 | AR104 Thermal Performance AR105 Referenced Standards |
929 | APPENDIX S STRAWBALE CONSTRUCTION Section AS101 General AS102 Definitions AS103 Bales |
931 | AS104 Finishes |
932 | AS105 Strawbale Walls—General |
937 | AS106 Strawbale Walls—Structural |
940 | AS107 Fire Resistance |
943 | AS108 Thermal Insulation AS109 Referenced Standards |
945 | APPENDIX T SOLAR-READY PROVISIONS— DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES Section T101 Scope T102 General Definition T103 Solar-ready Zone |
947 | INDEX |