{"id":146863,"date":"2024-10-19T08:37:02","date_gmt":"2024-10-19T08:37:02","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-iecc-2015-2\/"},"modified":"2024-10-25T00:53:23","modified_gmt":"2024-10-25T00:53:23","slug":"icc-iecc-2015-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-iecc-2015-2\/","title":{"rendered":"ICC IECC 2015"},"content":{"rendered":"
The IECC addresses energy efficiency on several fronts including cost savings, reduced energy usage, conservation of natural resources and the impact of energy usage on the environment.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2015 IECC Errata Introduction <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 2015 IECC Errata Chapter C1 – 1st, 2nd and 3rd PRINTINGS (January 12, 2016) <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | 2015 IECC Errata Chapter C3 – 1st PRINTING (November 10, 2014) <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | 2015 IECC Errata Chapter C4 – 1st and 2nd PRINTING (December 19, 2015) <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Exceptions: <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITI… <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | TABLE C403.2.3(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTS a, b, d <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | TABLE C403.2.1c C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c TABLE C403.3.1 DX COOLING STATESTAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS TABLE C405.4.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 2015 IECC Errata Chapter R2 – 1st and 2nd PRINTING (December 17, 2015) CHAPTER 2 [RE] DEFINITIONS <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 2015 IECC Errata Chapter R3 – 1st and 2nd PRINTING (December 17, 2015) CHAPTER 3 [RE] GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 2015 IECC Errata Chapter R4 – 1st and 2nd PRINTING (December 17, 2015) <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 2015 IECC Errata Chapter R5 – 1st and 2nd PRINTING (June 30, 2015) <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 2015 IECC Errata Appendix RA – 1st PRINTING TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" International Energy Conservation Code<\/b><\/p>\n |