{"id":154730,"date":"2024-10-19T09:12:34","date_gmt":"2024-10-19T09:12:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-iec-60780-323-2016\/"},"modified":"2024-10-25T01:28:01","modified_gmt":"2024-10-25T01:28:01","slug":"ieee-iec-60780-323-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-iec-60780-323-2016\/","title":{"rendered":"IEEE IEC 60780 323 2016"},"content":{"rendered":"
Revision Standard – Active. This standard is applicable to electrical equipment important to safety and its interfaces that are necessary to perform a safety function, or whose failure could adversely affect, the safety functions of other equipment. Electrical equipment in nuclear facilities shall meet its safety functional requirements throughout its installed life. This is accomplished by a thorough programme of quality assurance, design control, quality control, qualification, production, transportation, storage, installation, maintenance, periodic testing, and surveillance. This IEC\/IEEE standard specifically focuses on qualification. Other aspects, relating to quality assurance, reliability, selection and use of electronic devices, design and modification of digital systems including V&V activities are not part of this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEC\/IEEE 60780-323:2016 Front cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope and object 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Symbols and abbreviations 5 Principles of equipment qualification 5.1 Qualification objective <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Qualified life and qualified condition 5.3 Qualification elements 5.4 Qualification documentation <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6 Qualification methods 6.1 Initial qualification 6.1.1 Type testing 6.1.2 Operating experience 6.1.3 Analysis 6.1.4 Combined methods 6.2 Reassessing qualified life 6.2.1 General <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.2.2 Method 1: Using conservatism 6.2.3 Method 2: Type test on aged samples from the plant 6.2.4 Method 3: Performing type test for longer qualified life 6.2.5 Method 4: Component replacement 6.3 Condition monitoring <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7 Qualification program 7.1 General 7.2 Equipment specification 7.2.1 General 7.2.2 Equipment identification 7.2.3 Interfaces <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.2.4 Qualified life objective 7.2.5 Safety function(s) 7.2.6 Service conditions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.3 Qualification programme plan 7.3.1 General 7.3.2 Ageing 7.3.3 Significant ageing mechanisms <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.3.4 Qualified life objective 7.3.5 Service condition margin 7.3.6 Maintenance 7.3.7 Acceptance criteria 7.4 Qualification programme implementation 7.4.1 Type testing <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 1 \u2013 Minimal test margins recommended for DBEs <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 7.4.2 Operating experience <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.4.3 Qualification with analysis <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.4.4 Modifications 8 Documentation 8.1 General 8.2 General documentation requirements <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8.3 Specific documentation requirements for mild environment 8.4 Specific documentation requirements for harsh environment <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Bibliography <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Fran\u00e7ais SOMMAIRE <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | AVANT-PROPOS <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 1 Domaine d\u2019application et objet 2 R\u00e9f\u00e9rences normatives 3 Termes et d\u00e9finitions <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 4 Symboles et abr\u00e9viations <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 5 Principes de qualification des \u00e9quipements 5.1 Objectif de la qualification 5.2 Dur\u00e9e de vie qualifi\u00e9e et \u00e9tat qualifi\u00e9 <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 5.3 El\u00e9ments de qualification 5.4 Documentation de qualification 6 M\u00e9thodes de qualification 6.1 Qualification initiale 6.1.1 Essais de type 6.1.2 Retour d\u2019exp\u00e9rience en exploitation <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 6.1.3 Analyse 6.1.4 M\u00e9thodes mixtes 6.2 R\u00e9\u00e9valuation de la dur\u00e9e de vie qualifi\u00e9e 6.2.1 G\u00e9n\u00e9ralit\u00e9s 6.2.2 M\u00e9thode 1: Utilisation des conservatismes 6.2.3 M\u00e9thode 2: Essais de type sur \u00e9quipement pr\u00e9l\u00e8v\u00e9 dans l\u2019installation <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 6.2.4 M\u00e9thode 3: Essais de type pour une p\u00e9riode qualifi\u00e9e \u00e9tendue 6.2.5 M\u00e9thode 4: Remplacement de composant 6.3 Surveillance d\u2019\u00e9tat de d\u00e9gradation <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7 Programme de qualification 7.1 G\u00e9n\u00e9ralit\u00e9s 7.2 Sp\u00e9cifications de l\u2019\u00e9quipement 7.2.1 G\u00e9n\u00e9ralit\u00e9s 7.2.2 Identification de l\u2019\u00e9quipement 7.2.3 Interfaces 7.2.4 Objectif de dur\u00e9e de vie qualifi\u00e9e <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 7.2.5 Fonction(s) de s\u00fbret\u00e9 7.2.6 Conditions de service <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 7.3 Programme de qualification 7.3.1 G\u00e9n\u00e9ralit\u00e9s 7.3.2 Vieillissement <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 7.3.3 M\u00e9canismes de vieillissement significatifs 7.3.4 Objectif de dur\u00e9e de vie qualifi\u00e9e 7.3.5 Marges associ\u00e9es aux conditions de service 7.3.6 Maintenance <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 7.3.7 Crit\u00e8res d\u2019acceptation 7.4 Mise en \u0153uvre du programme de qualification 7.4.1 Essais de type <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Tableau 1 \u2013 Marges minimales d\u2019essai recommand\u00e9es pour les EDD <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 7.4.2 Retour d\u2019exp\u00e9rience en exploitation <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 7.4.3 Qualification par analyse <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 7.4.4 Modifications <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 8 Documentation 8.1 G\u00e9n\u00e9ralit\u00e9s 8.2 Exigences g\u00e9n\u00e9rales de documentation <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 8.3 Exigences de documentation sp\u00e9cifiques pour les environnements peu s\u00e9v\u00e8res 8.4 Exigences de documentation sp\u00e9cifiques pour les environnements s\u00e9v\u00e8res <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Bibliographie <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEC\/IEEE Draft International Standard – Nuclear Facilities – Electrical Equipment Important to Safety -Qualification<\/b><\/p>\n |