{"id":222172,"date":"2024-10-19T14:25:18","date_gmt":"2024-10-19T14:25:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-5502-501993a22010\/"},"modified":"2024-10-25T08:00:28","modified_gmt":"2024-10-25T08:00:28","slug":"bs-5502-501993a22010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-5502-501993a22010\/","title":{"rendered":"BS 5502-50:1993+A2:2010"},"content":{"rendered":"

This Part of BS 5502 gives recommendations for the design, construction and use of agricultural storage tanks and reception pits for livestock slurry.<\/p>\n

\n

NOTE Further sources of information are given in Appendix A. The titles of the publications referred to in this standard are listed on page 24.<\/p>\n<\/blockquote>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nBRITISH STANDARD <\/td>\n<\/tr>\n
2<\/td>\nCommittees responsible for this British Standard <\/td>\n<\/tr>\n
3<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\n1 Scope
2 Definitions and symbols
2.1 Definitions
2.1.1 slurry
2.1.2 slurry storage tank
2.1.3 reception pit
2.2 Symbols
2.2.1 General
2.2.2 Slurry storage tank <\/td>\n<\/tr>\n
8<\/td>\nFigure 1 Symbols
2.2.3 Reception pit <\/td>\n<\/tr>\n
9<\/td>\n3 Siting of slurry storage tanks and reception pits
3.1 General
3.2 !Emissions to air
3.3 Pollution control <\/td>\n<\/tr>\n
10<\/td>\n3.4 Other considerations
4 Sizing of slurry storage tanks and reception pits
4.1 General
4.2 Amounts of waste produced by livestock
4.3 Amounts of dirty water produced
4.4 Slurry storage tank size
4.5 Reception pit size <\/td>\n<\/tr>\n
11<\/td>\n5 Loads
5.1 General
5.2 Slurry loads
5.3 Wind loads
5.4 Pressures on reception pits and below ground tanks <\/td>\n<\/tr>\n
12<\/td>\nTable 1 Soil\/backfill data
Figure 2 Soil\/backfill and slurry loading example for reception pits <\/td>\n<\/tr>\n
13<\/td>\nFigure 3 Surcharge from point load
5.4.3.2 Surcharge from uniform load <\/td>\n<\/tr>\n
14<\/td>\nFigure 5 Surcharge from isolated foundation
5.5 Reception pit cover\/grid loadings
5.6 Machinery loading
6 Structural design
6.1 General
6.2 Walls and floors <\/td>\n<\/tr>\n
15<\/td>\n6.3 Cylindrical steel plate tanks
Table 2 Effective second moment of area for wind stiffeners !for open tanks”
6.4 Concrete stave tanks <\/td>\n<\/tr>\n
16<\/td>\n6.5 Earth bank lagoons
6.6 Covers for stores <\/td>\n<\/tr>\n
17<\/td>\n7 Materials
7.1 General
7.2 Corrosion protection <\/td>\n<\/tr>\n
18<\/td>\n7.3 Joints, sealing and waterproofing
8 Safety
8.1 General
8.2 Guarding of slurry storage tanks and reception pits
8.3 Access to slurry storage tanks
8.4 Access to covered reception pits <\/td>\n<\/tr>\n
19<\/td>\n8.5 Valves
8.6 Extension to height
8.7 Notices <\/td>\n<\/tr>\n
20<\/td>\n9 Operation and maintenance manual <\/td>\n<\/tr>\n
21<\/td>\nBibliography
Bibliography
A.1 Legislation
A.2 Supporting information <\/td>\n<\/tr>\n
22<\/td>\nAppendix B Design methodology for slurry storage tanks constructed with concrete staves
Design methodology for slurry storage tanks constructed with concrete staves
B.1 Symbols
B.2 General <\/td>\n<\/tr>\n
23<\/td>\nB.3 Stresses caused by slurry pressure
B.4 Stresses caused by hydrostatic prestress
B.5 Stresses caused by single band of prestress at top of tank <\/td>\n<\/tr>\n
24<\/td>\nB.6 Stresses caused by wind pressure <\/td>\n<\/tr>\n
25<\/td>\nB.7 Stresses caused by wind prestress
B.8 Combination of load cases
B.8.1 General
B.8.2 Prestress alone
B.8.3 Prestress plus slurry <\/td>\n<\/tr>\n
26<\/td>\nB.8.4 Prestress plus slurry plus wind
B.8.5 Prestress plus wind <\/td>\n<\/tr>\n
27<\/td>\nB.8.6 Examination of load cases <\/td>\n<\/tr>\n
29<\/td>\nAppendix C Checklist for the operators of slurry storage tanks and reception pits
Checklist for the operators of slurry storage tanks and reception pits <\/td>\n<\/tr>\n
31<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Buildings and structures for agriculture – Code of practice for design, construction and use of storage tanks and reception pits for livestock slurry<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2010<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":222176,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[922,2641],"product_tag":[],"class_list":{"0":"post-222172","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-65-040-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/222172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/222176"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=222172"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=222172"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=222172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}