{"id":236541,"date":"2024-10-19T15:26:25","date_gmt":"2024-10-19T15:26:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60297-3-1072012\/"},"modified":"2024-10-25T10:03:38","modified_gmt":"2024-10-25T10:03:38","slug":"bs-en-60297-3-1072012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60297-3-1072012\/","title":{"rendered":"BS EN 60297-3-107:2012"},"content":{"rendered":"
IEC 60297-3-107:2012 defines the interface dimensions between subracks and associated plug-in units using connectors as defined in PICMG-MTCA.0 (Fixed board, see Figure 7) and IEC 61076-4-116 (Two part, see Figure 12) and other two part connectors, (see Figure 15). For mechanical and climatic tests refer to IEC 61587-1. For electromagnetic shielding performance tests refer to IEC 61587-3.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope and object 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Arrangement overview (4U shown) Figures Figure 1 \u2013 Arrangement overview <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Subrack dimensions 4.1 Subrack dimensions front mounting area <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 2 \u2013 Subrack dimensions, front view <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 3 \u2013 Subrack dimensions, side view <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.2 Subrack dimensions, rear view, backplane mounting area Figure 4 \u2013 Subrack dimensions, top view Figure 5 \u2013 Subrack dimensions, rear view <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 Plug-in unit dimensions Figure 6 \u2013 Plug-in unit dimensions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6 Connector and related printed board dimensions 6.1 Connector according to PICMG-MicroTCA.0\/ IEC\u00a061076-4-116, fixed board connector and related printed board dimensions 6.1.1 PICMG- MicroTCA.0\/ IEC\u00a061076-4-116 connector, isometric view 6.1.2 Connector according to PICMG- MicroTCA.0\/ IEC\u00a061076-4-116, fixed board connector and related printed board \u2013 arrangement overview Figure 7 \u2013 PICMG- MicroTCA.0\/ IEC\u00a061076-4-116 connector, isometric view Figure 8 \u2013 PICMG- MicroTCA.0\/ IEC\u00a061076-4-116 fixed board connector, arrangement overview \u2013 Top view <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.1.3 Printed board dimensions Figure 9 \u2013 Printed board dimensions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.1.4 Printed board dimensions, 4U example Figure 10 \u2013 Printed board dimensions, 4U example <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.1.5 Connector according to PICMG-MTCA.0, fixed board connector dimensions 6.2 Two part connector according to IEC\u00a061076-4-116 and related printed board dimensions 6.2.1 Two part connector, isometric view Figure 11 \u2013 Connector according to PICMG- MTCA.0, fixed board connector dimensions Figure 12 \u2013 Fixed board and free board connector \u2013 Isometric view <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2.2 Two part connector, arrangement overview 6.2.3 Two part connector, printed board dimensions Figure 13 \u2013 Two part connector, arrangement overview \u2013 Top view Figure 14 \u2013 Two part connector, printed board dimensions <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.2.4 Two part connector, fixed board connector dimensions 6.3 Two part connector with PIU PB component side attachment features 6.3.1 Two part connector, arrangement overview 6.3.2 Two part connector, printed circuit board dimensions, 2 U Figure 15 \u2013 Two part connector, arrangement overview \u2013 Top view Figure 16 \u2013 Two part connector, dimensions, 2 U <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.3.3 Two part connector, connector mounted on backplane, 2 U Figure 17 \u2013 Two part connector, connector mounted on backplane dimensions, 2 U <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7 Backplane dimensions 7.1 Backplane dimensions using two part connector according to IEC\u00a061076-4-116 <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 18 \u2013 Backplane dimensions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8 Subrack and plug-in units with electromagnetic shielding (EMC) provisions 8.1 General 8.2 Subrack EMC provisions Figure 19 \u2013 Subrack EMC dimensions <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8.3 Plug-in unit and filler panels EMC provisions 9 Subrack and plug in units electrostatic discharge provisions (ESD) 9.1 General Figure 20 \u2013 Plug-in unit EMC dimensions <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 9.2 Subrack ESD provisions Figure 21 \u2013 Subrack ESD provision <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 9.3 Plug\u2013in unit ESD provisions, front mounted Figure 22 \u2013 Plug-in unit ESD provision Tables Table 1 \u2013 Height dimensions <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 10 Nomenclature Table 2 \u2013 Depth dimensions <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex A (informative) Connector hole pattern at the backplane Figure A.1 \u2013 Connector pin location according to IEC\u00a061076-4-116, front view <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex B (informative) Rear mounted plug-in unit implementation Figure B.1 \u2013 Depth dimension subrack type 1, side view Figure B.2 \u2013 Depth dimension subrack type 2, side view <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure B.3 \u2013 Depth dimension subrack type 3, side view <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex C (informative) Hot swap latch function <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex D (informative) Subrack latch mechanism interface dimensionsfor ruggedized applications <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex E (informative) Subrack ESD contact interface dimensions <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Mechanical structures for electronic equipment. Dimensions of mechanical structures of the 482,6 mm (19 in) series – Dimensions of subracks and plug-in units, small form factor<\/b><\/p>\n |