{"id":244568,"date":"2024-10-19T16:04:11","date_gmt":"2024-10-19T16:04:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61003-12016\/"},"modified":"2024-10-25T11:03:32","modified_gmt":"2024-10-25T11:03:32","slug":"bs-en-61003-12016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61003-12016\/","title":{"rendered":"BS EN 61003-1:2016"},"content":{"rendered":"
This part of IEC 61003<\/span> <\/span> is applicable to pneumatic and electric industrial-process instruments or control device using measured values that are continuous signals either a mechanical (position, force, etc.) or a standard electric signal.<\/p>\n These instruments or process control systems modules may be used as controllers or as switches for alarm and other similar purposes.<\/p>\n Electronic product safety issues may impact only a few products covered by this document. Consequently this document does not address such safety issues.<\/p>\n This standard is intended to specify uniform terminologies and testing methods for performance evaluation of industrial-process instruments or process control systems modules with analogue measured values and two- or multi-position outputs.<\/p>\n Considerations other than the performances are listed in Clause 10<\/span>.<\/p>\n Industrial-process control systems. Instruments with analogue inputs and two- or multi-position outputs – Methods for evaluating performance<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n European foreword
Endorsement notice <\/td>\n<\/tr>\n\n 5<\/td>\n Annex ZA (normative) Normative references to international publications with their corresponding European publications <\/td>\n<\/tr>\n \n 6<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 8<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 10<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 11<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 12<\/td>\n 3 Terms and definitions
Figure 1 \u2013 Action of two-position output <\/td>\n<\/tr>\n\n 13<\/td>\n 4 General conditions for tests
4.1 Documentary information
4.1.1 General reference documents
Figure 2 \u2013 Action of three-position output <\/td>\n<\/tr>\n\n 14<\/td>\n 4.1.2 Collect data
4.2 Electrical safety
4.3 Installation
4.4 Supply conditions
5 General testing procedures and precautions
5.1 Checking of calibration made prior to delivery
5.2 Set point <\/td>\n<\/tr>\n\n 15<\/td>\n 5.3 Differential gap
6 Test methods and procedures
6.1 Tests under reference conditions
6.1.1 Switching accuracy related factors <\/td>\n<\/tr>\n\n 16<\/td>\n 6.1.2 Mean switching point
6.1.3 Set point
6.2 Tests for the effects of influence quantities
6.2.1 Ambient temperature <\/td>\n<\/tr>\n\n 17<\/td>\n 6.2.2 Humidity
6.2.3 Vibrations <\/td>\n<\/tr>\n\n 18<\/td>\n 6.2.4 Shock, drop and topple
6.2.5 Mounting position
6.2.6 Over-range
6.2.7 Output load effects
6.2.8 Supply voltage and frequency variations
6.2.9 Short-term supply voltage interruptions <\/td>\n<\/tr>\n\n 19<\/td>\n 6.2.10 Fast transient\/burst immunity requirements
6.2.11 Supply pressure variations
6.2.12 Common mode interference
6.2.13 Normal mode interference (series mode)
6.2.14 Earthing
6.2.15 Magnetic field effects <\/td>\n<\/tr>\n\n 20<\/td>\n 6.2.16 Electromagnetic field
6.2.17 Electrostatic discharge (ESD)
6.2.18 Effect of open-circuited and short-circuited input
6.2.19 Effect of open-circuited and short-circuited output
6.2.20 Effect of process medium temperature <\/td>\n<\/tr>\n\n 21<\/td>\n 6.2.21 Atmospheric pressure effects
6.2.22 Start-up drift
6.2.23 Accelerated operational life test
6.3 Other tests
6.3.1 Transient response of a two-position output <\/td>\n<\/tr>\n\n 22<\/td>\n 6.3.2 Indication of the measured value
6.3.3 Adjustable differential gap
6.3.4 Dielectric strength <\/td>\n<\/tr>\n\n 23<\/td>\n 6.3.5 Insulation resistance
7 Multi-position output
7.1 Action
7.2 Test
7.2.1 Characteristics of the multi-position output
7.2.2 Mutual influence of pairs of switching points
7.2.3 Determination of switching range
8 General observations
8.1 Protective finishes
8.2 Tools and equipment <\/td>\n<\/tr>\n\n 24<\/td>\n 9 Test report and summary of tests
Table 1 \u2013 An example of a report (1 of 4) <\/td>\n<\/tr>\n\n 27<\/td>\n 10 Partial evaluation <\/td>\n<\/tr>\n \n 28<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":244571,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[697,2641],"product_tag":[],"class_list":{"0":"post-244568","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-35-240-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/244568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/244571"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=244568"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=244568"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=244568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}