{"id":276233,"date":"2024-10-19T18:35:29","date_gmt":"2024-10-19T18:35:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-cen-tr-170862020\/"},"modified":"2024-10-25T15:01:41","modified_gmt":"2024-10-25T15:01:41","slug":"bsi-pd-cen-tr-170862020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-cen-tr-170862020\/","title":{"rendered":"BSI PD CEN\/TR 17086:2020"},"content":{"rendered":"
This document explains the reasoning behind the requirements and procedures given in EN 13791<\/span><\/span> [1<\/span>] and why some concepts and procedures given in EN 13791:2007<\/span><\/span> [2<\/span>] were not adopted in the 2019 revision. The annex comprises worked examples of the procedures given in EN 13791:2019<\/span><\/span>.<\/p>\n Further guidance on the application of EN 13791:2019 and background to the provisions<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 8<\/td>\n 1 Scope
2 Symbols and abbreviated terms <\/td>\n<\/tr>\n\n 9<\/td>\n 3 General principles adopted for the revision <\/td>\n<\/tr>\n \n 10<\/td>\n 4 In situ compressive strength and other concrete properties assumed in the EN 1992-1-1 design process
4.1 General <\/td>\n<\/tr>\n\n 11<\/td>\n 4.2 Concrete compressive strength based on test specimens <\/td>\n<\/tr>\n \n 13<\/td>\n 4.3 Concrete compressive strength based on the strength of cores from the structure
5 Differences between test specimens and concrete in the structure
5.1 Introduction <\/td>\n<\/tr>\n\n 14<\/td>\n 5.2 Reference test specimen <\/td>\n<\/tr>\n \n 15<\/td>\n 5.3 Effects of the moisture condition on in situ specimens <\/td>\n<\/tr>\n \n 16<\/td>\n 5.4 Effect of maturity on concrete strength
5.5 Effects of curing <\/td>\n<\/tr>\n\n 17<\/td>\n 5.6 Effects of vibration
5.7 Effects of excess entrapped air
6 Testing variables that influence core strength
6.1 Introduction
6.2 Direction relative to the casting
6.3 Imperfections <\/td>\n<\/tr>\n\n 18<\/td>\n 6.4 Diameter of core
6.5 Length\/diameter ratio
6.6 Flatness of end surfaces
6.7 Capping of end surfaces
6.8 Effect of drilling
6.9 Reinforcement <\/td>\n<\/tr>\n\n 19<\/td>\n 7 Scope in EN 13791:2019, Clause 1
8 Terms and definitions, symbols and abbreviations in EN 13791:2019, Clause 3 <\/td>\n<\/tr>\n\n 20<\/td>\n 9 Investigation objective and test parameters in EN 13791:2019, Clause 4
10 Test regions and test locations in EN 13791:2019, Clause 5
11 Core testing and the determination of the in situ compressive strength in EN 13791:2019, Clause 6 <\/td>\n<\/tr>\n\n 21<\/td>\n 12 Initial evaluation of the data set in EN 13791:2019, Clause 7 <\/td>\n<\/tr>\n \n 22<\/td>\n 13 Estimation of compressive strength for structural assessment of an existing structure in EN 13791:2019, Clause 8
13.1 Based on core test data only (see EN 13791:2019, 8.1) <\/td>\n<\/tr>\n\n 27<\/td>\n 13.2 Based on a combination of indirect test data and core test data (see EN 13791:2019, 8.2) <\/td>\n<\/tr>\n \n 32<\/td>\n 13.3 Use of indirect testing with selected core testing (see EN 13791:2019, 8.3)
14 Assessment of compressive strength class of supplied concrete in case of doubt in EN 13791:2019, Clause 9
14.1 General in EN 13791:2019, 9.1 <\/td>\n<\/tr>\n\n 33<\/td>\n 14.2 Use of core test data (see EN 13791:2019, 9.2) <\/td>\n<\/tr>\n \n 34<\/td>\n 14.3 Indirect testing plus selected core testing (see EN 13791:2019, 9.3)
14.4 Screening test using general or specific relationship with an indirect test procedure (see EN 13791:2019, 9.4) <\/td>\n<\/tr>\n\n 38<\/td>\n 14.5 Procedure where the producer has declared non-conformity of compressive strength in EN 13791:2019, 9.5
14.6 Use of comparative testing <\/td>\n<\/tr>\n\n 41<\/td>\n Annex A (informative)Examples of the calculations
A.1 Example A1: Calculating the rebound number <\/td>\n<\/tr>\n\n 43<\/td>\n A.2 Example A2: Calculating the in situ strength from core test data
A.2.1 Example A2.1
A.2.2 Example A2.2 <\/td>\n<\/tr>\n\n 44<\/td>\n A.3 Example A3: Assessing the data for a test region to check whether it contains two or more compressive strength classes <\/td>\n<\/tr>\n \n 47<\/td>\n A.4 Example A4: Check for statistical outliers <\/td>\n<\/tr>\n \n 49<\/td>\n A.5 Example A5: Calculation of characteristic in situ compressive strength from core test data <\/td>\n<\/tr>\n \n 50<\/td>\n A.6 Example A6: Establishing a correlation between an indirect test and in situ compressive strength <\/td>\n<\/tr>\n \n 54<\/td>\n A.7 Example A7: Using combined indirect testing and core testing to estimate the characteristic in situ compressive strength and the compressive strength at a location where only an indirect test result is available <\/td>\n<\/tr>\n \n 57<\/td>\n A.8 Example A8: Estimating the characteristic in situ compressive strength using indirect testing and three cores taken from the weaker area
A.8.1 Example A8.1
A.8.2 Example A8.2 <\/td>\n<\/tr>\n\n 58<\/td>\n A.9 Example A9: Screening test using a generic relationship <\/td>\n<\/tr>\n \n 61<\/td>\n A.10 Example A10: Screening test using a rebound hammer that has been calibrated against test specimens made from the same concrete <\/td>\n<\/tr>\n \n 65<\/td>\n A.11 Example A11: Assessment of compressive strength class of concrete as placed using indirect testing and selected core test data <\/td>\n<\/tr>\n \n 66<\/td>\n A.12 Example A12: Assessment of compressive strength class of recently supplied concrete using core test data only <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":276240,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1249,2641],"product_tag":[],"class_list":{"0":"post-276233","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-080-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/276233","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/276240"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=276233"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=276233"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=276233"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}