{"id":288288,"date":"2024-10-19T19:32:58","date_gmt":"2024-10-19T19:32:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-8468-3-12020\/"},"modified":"2024-10-25T16:27:10","modified_gmt":"2024-10-25T16:27:10","slug":"bs-8468-3-12020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-8468-3-12020\/","title":{"rendered":"BS 8468-3.1:2020"},"content":{"rendered":"
This British Standard specifies requirements for self-contained open-circuit compressed air breathing apparatus incorporating a hood, intended to be used only during escape by emergency responders (\ufb01re, ambulance, police) and adult civilians from areas contaminated by chemical, biological, radiological and nuclear (CBRN) agents.<\/p>\n
This British Standard is applicable to Type ES CBRN devices. Type ES CBRN devices provide resistance to liquid and gaseous chemical agent permeation and penetration and provide protection capability against hazardous particulate matter.<\/p>\n
This British Standard contains requirements for classi\ufb01cation, testing and marking of the device.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4 Classification 5 Requirements 5.1 General 5.2 Preconditioning 5.3 Visual inspection 5.4 Inward leakage 5.5 Chemical agent permeation and penetration <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Figure 1 \u2014 Schematic diagram of HD agent droplet placement on hood and supply hose Figure 2 \u2014 Schematic diagram of HD agent droplet placement between hood and cylinder thread <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.6 Donning 6 Marking 7 Information supplied by the manufacturer <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Respiratory protective devices for use against chemical, biological, radiological and nuclear (CBRN) agents – Self-contained open-circuit compressed air breathing apparatus incorporating a hood for escape. Speci\ufb01cation<\/b><\/p>\n |