{"id":361936,"date":"2024-10-20T01:38:20","date_gmt":"2024-10-20T01:38:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-230702020\/"},"modified":"2024-10-26T02:33:27","modified_gmt":"2024-10-26T02:33:27","slug":"bs-iso-230702020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-230702020\/","title":{"rendered":"BS ISO 23070:2020"},"content":{"rendered":"
This document provides guidelines for the planning and design of a reverse osmosis (RO) treatment system of municipal wastewater. This document is applicable to practitioners and authorities who intend to implement principles and decisions on RO treatment of municipal wastewater in a safe, reliable and sustainable manner. This document addresses RO treatment systems of municipal wastewater in their entirety and is applicable to any RO treatment system component.<\/p>\n
This document provides:<\/p>\n
standard terms and definitions;<\/p>\n<\/li>\n
a description of the system components of an RO treatment system of municipal wastewater;<\/p>\n<\/li>\n
design principles of an RO treatment system of municipal wastewater;<\/p>\n<\/li>\n
statements on the feed water quality and technical requirements of an RO treatment system;<\/p>\n<\/li>\n
guidance for operation and maintenance of an RO treatment system;<\/p>\n<\/li>\n
specific aspects for consideration and emergency response.<\/p>\n<\/li>\n<\/ul>\n
Design parameters and regulatory values of an RO treatment system of municipal wastewater are out of the scope of this document.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Abbreviated terms 5 Application of RO treatment systems for reclaimed water 5.1 Overview <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.2 Design considerations 5.2.1 Safety considerations 5.2.2 Stability considerations 5.2.3 Economy considerations 5.3 RO system components 5.3.1 General <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.3.2 Feed water source 5.3.3 Pre-treatment unit 5.3.4 RO treatment unit 5.3.5 Auxiliary equipment 5.3.6 Post treatment unit 5.3.7 Water quality and performance monitoring system 6 Technical considerations of pre-treatments 6.1 Quality considerations of feed water 6.1.1 General water quality index <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.1.2 Silt density index 6.1.3 Organic index <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.1.4 Biological index 6.1.5 Oxidation-reduction potential 6.2 Selection of mechanical pre-treatments 6.2.1 Clarification 6.2.2 Media\/Multimedia filtration 6.2.3 Activated carbon filtration <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2.4 Microfiltration and ultrafiltration 6.2.5 Cartridge filtration 6.3 Chemical pre-treatments 6.3.1 Antiscalants 6.3.2 Chemical oxidizers for disinfection of the feed 6.3.3 Reductants 6.3.4 Non-oxidizing biocides 7 Technical and structural considerations of RO unit 7.1 Components 7.1.1 RO feed pumps <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.1.2 RO membrane modules 7.1.3 Pressure vessels 7.2 Selection of RO membranes 7.2.1 Membrane materials <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7.2.2 Membrane modules 7.3 RO unit configuration <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8 Operating conditions and maintenance system 8.1 Operating conditions 8.1.1 Pressure 8.1.2 Temperature 8.1.3 Feed water flow and permeate flux 8.1.4 Concentrate flow <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.1.5 pH 8.2 RO performance parameters 8.2.1 Permeate flow rate <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.2.2 Salt rejection 8.2.3 Pressure drop 8.3 Automatic chemical dosing system 8.3.1 Dosing point 8.3.2 Dosing method 8.4 Control and monitor system of RO performance 8.4.1 Instrumentation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.4.2 Control system 8.4.3 Monitoring system 8.5 Cleaning system 8.5.1 Physical cleaning 8.5.2 Chemical cleaning <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.6 Integrity testing of RO systems <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.7 System failure <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 9 Post-treatment unit 10 RO concentrate management 11 Emergency response plan <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex A (informative) Example of an RO treatment system for reclaimed water <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex B (informative) Information of chlorine disinfection for the influent of an RO system <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex C (informative) Maturity level of technologies applied to RO concentrate treatment <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Water Reuse in Urban Areas. Guidelines for reclaimed water treatment: Design principles of a RO treatment system of municipal wastewater<\/b><\/p>\n |