{"id":409541,"date":"2024-10-20T05:36:03","date_gmt":"2024-10-20T05:36:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-12259-142020a12022\/"},"modified":"2024-10-26T10:16:36","modified_gmt":"2024-10-26T10:16:36","slug":"bs-en-12259-142020a12022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-12259-142020a12022\/","title":{"rendered":"BS EN 12259-14:2020+A1:2022"},"content":{"rendered":"
This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat and incorporating the following types of water seals: – conical metal spring with a PTFE gasket or coating; – metal cap or disc with PTFE gasket or coating; – copper gasket, with or without a PTFE coating. Sprinklers in accordance with this document will only be used in automatic sprinkler systems for domestic and residential applications as defined in EN 16925.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 Construction and performance 4.1 General 4.2 Dimensions and pressure rating 4.2.1 Dimensions 4.2.2 Pressure ratings 4.3 Nominal operating temperature <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.4 Operating temperatures 4.5 Water flow and distribution 4.5.1 K-factor 4.5.2 Water distribution 4.5.2.1 Water distribution test \u2013 Horizontal surface <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.5.2.2 Water distribution test \u2013 Vertical surface 4.5.3 Water Impingement Test 4.6 Function 4.7 Fire Test <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.8 Strength of sprinkler body and deflector 4.8.1 Strength of frame 4.8.2 Flow endurance 4.8.3 Strength of deflector 4.9 Strength of release element 4.9.1 Glass bulb sprinklers <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.9.2 Fusible link sprinklers 4.10 Leak resistance and hydrostatic strength 4.11 Heat exposure 4.11.1 General <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.11.2 Additional heat exposure of glass bulb sprinklers 4.11.3 Thermal shock 4.12 Corrosion 4.12.1 Stress corrosion 4.12.2 Sulphur dioxide corrosion 4.12.3 Salt mist corrosion 4.12.4 Moist air 4.13 Water hammer <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.14 Thermal response 4.14.1 Oven test 4.14.2 Room response test 4.15 Resistance to vibration 4.16 Resistance to impact 4.17 Resistance to low temperature 4.18 Resistance to heat 4.19 Test conditions 5 Marking 5.1 General 5.2 Identification number <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.3 Nominal operating temperature and year of manufacture 5.4 Manufacturing location 5.5 Heat sensitive element supplier 5.6 Protective covers 5.7 Sidewall sprinklers 5.7.1 General 5.7.2 Horizontal sidewall sprinklers 5.8 Concealed sprinklers <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.9 Removable recessed housing 6 Instruction charts 6.1 General 6.2 Installation Instructions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex A (normative)Conditions for tests <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex B (normative)Water flow test <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex C (normative)Water distribution test C.1 Water distribution test \u2013 Horizontal surface C.1.1 General C.1.2 Upright, pendant, flush, recessed and concealed sprinklers <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | C.1.3 Sidewall Sprinklers <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | C.2 Water distribution test \u2013 vertical surface C.2.1 Test method <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | C.3 Water impingement test <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex D (normative)Fire test D.1 Extent of testing <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | D.2 Test arrangement D.2.1 Test room <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | D.2.2 Fire source <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | D.2.3 Sprinkler installation <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | D.3 Test method <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | D.4 Supplementary test <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Annex E (normative)Function test E.1 Function test E.2 Verification function test <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex F (normative)Strength of sprinkler body and deflector F.1 Strength of sprinkler bod <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | F.2 Flow endurance test F.3 Deflector strength test <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Annex G (normative)Strength of release elements test G.1 Glass bulbs <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | G.2 Fusible links <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex H (normative)Leak resistance tests H.1 Leak Test H.2 Hydrostatic Strength Test <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Annex I (normative)Heat exposure I.1 High temperature test I.2 Additional testing of glass bulb sprinklers <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Annex J (normative)Glass bulb sprinkler thermal shock test <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex K (normative)Exposure and corrosion tests K.1 Stress corrosion K.1.1 Sample preparation K.1.2 Apparatus K.1.3 Procedure K.2 Sulphur dioxide corrosion K.2.1 Reagents for apparatus of 5 l volume <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | K.2.2 Apparatus K.2.3 Procedure <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | K.3 Salt mist corrosion K.3.1 Reagents K.3.2 Apparatus K.3.3 Procedure <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | K.4 Moist Air K.4.1 Performance criteria K.4.2 Procedure <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex L (normative)Water hammer test <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex M (normative)Thermal response test M.1 Oven heat test <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | M.2 Room heat test M.2.1 Flush, recessed or concealed sprinklers M.2.2 Sprinkler location and orientation M.2.3 Room dimensions and water supply <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | M.2.4 Fire source and distance to sprinkler <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Annex N (normative)Vibration test N.1 Sample preparation and performance criteria N.2 Procedure <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Annex O (normative)Impact test <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Annex P (normative)Resistance to low temperature test <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Annex Q (normative)Resistance to high temperature test <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fixed firefighting systems. Components for sprinkler and water spray systems – Sprinklers for residential applications<\/b><\/p>\n |