FEMA P942 2013
$53.95
FEMA P-942 Hurricane Sandy in New Jersey and New York
Published By | Publication Date | Number of Pages |
FEMA | 2013 | 223 |
Building Performance Observations, Recommendations, and Technical Guidance
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | Inside Cover |
3 | Title Page |
4 | Members of the Mitigation Assessment Team |
5 | Dedication |
6 | Header Photograph Description |
7 | Executive Summary |
8 | Mitigation Assessment Team Deployment and Observations MAT Recommendations Climate Change and Sea Level Rise |
9 | Building Codes and Standards Flood Protection Residential Construction |
11 | Critical Facilities and Key Assets Mechanical, Electrical, and Plumbing Systems |
13 | Contents |
18 | Appendices List of Figures |
26 | List of Tables |
28 | Acronyms and Abbreviations |
29 | Chapter 1. Introduction |
30 | 1.1 Organization of Report |
31 | 1.2 Background 1.2.1 Hurricane Sandy – The Event |
34 | 1.2.2 Regional Preparedness Actions |
36 | 1.2.3 FEMA Mitigation Assessment Team |
40 | 1.3 Summary of Damage Observed |
41 | 1.4 Flood Zones and Issuance of Updated Flood Hazard Information 1.4.1 FIRMs and Flood Zones |
42 | 1.4.2 Advisory Base Flood Elevation Maps |
43 | 1.4.3 New FIRMs |
45 | Chapter 2. Building Codes, Standards, and Regulations |
47 | 2.1 State of New Jersey 2.2 New York State |
48 | 2.3 New York City |
49 | 2.4 Guidelines and Standards for Healthcare Facilities |
51 | Chapter 3. Performance of Low-Rise Buildings |
53 | 3.1 Performance Relative to Flood and Erosion 3.1.1 Effect of Siting on Building Performance |
54 | 3.1.1.1 Building Location and Wave Exposure |
56 | 3.1.1.2 Beach and Dune Condition |
60 | 3.1.1.3 Barrier Island Breaches |
62 | 3.1.1.4 Features and Structures That Focus Flow 3.1.1.5 Proximity to Erosion Control Structures |
65 | 3.1.1.6 Proximity to Flood-Borne Debris Sources |
67 | 3.1.2 Elevation and Freeboard |
70 | 3.1.3 Foundation Performance |
80 | 3.1.4 Connections between Foundation and Building |
85 | 3.1.5 Basements and Subgrade Areas |
88 | 3.1.6 Mechanical, Electrical, and Plumbing Systems |
90 | 3.2 Performance Relative to Wind |
92 | 3.2.1 Main Wind Force Resisting System |
93 | 3.2.2 Building Envelope Damage |
97 | 3.3 Mold |
99 | Chapter 4. Performance of Mid- and High-Rise Buildings |
100 | 4.1 Mid-Rise Buildings 4.1.1 Siting Effects on Building Performance |
101 | 4.1.2 Structural Performance |
102 | 4.1.3 Critical Building Systems |
106 | 4.1.4 Conveyance/Elevators |
109 | 4.2 High-Rise Buildings 4.2.1 Siting Effects on Building Performance |
111 | 4.2.2 Structural Performance |
114 | 4.2.3 Critical Building Systems |
122 | 4.2.4 Conveyance/Elevators |
123 | Chapter 5. Performance of Critical Facilities and Key Assets |
124 | 5.1 Background 5.1.1 Critical Facilities Visited by the MAT |
125 | 5.1.2 General Preparedness |
126 | 5.2 Healthcare Facilities |
128 | 5.2.1 Facility Location and Construction |
129 | 5.2.2 Preparing for Hurricane Sandy |
131 | 5.2.3 Level of Flooding and Resulting Damage |
132 | 5.2.4 Effect on Operations and Functionality |
133 | 5.2.5 Recovery Actions and Issues |
135 | 5.3 First Responders: Police and Fire |
137 | 5.3.1 Facility Location and Construction 5.3.2 Preparing for Hurricane Sandy 5.3.3 Level of Flooding and Resulting Damage 5.3.4 Effect on Operations and Functionality |
138 | 5.3.5 Recovery Actions and Issues 5.4 Schools |
140 | 5.4.1 Facility Location and Construction 5.4.2 Preparing for Hurricane Sandy 5.4.3 Level of Flooding and Resulting Damage 5.4.4 Effect on Operations and Functionality 5.4.5 Recovery Actions and Issues |
141 | 5.5 Data Centers |
142 | 5.5.1 Facility Location and Construction |
143 | 5.5.2 Preparing for Hurricane Sandy 5.5.3 Level of Flooding and Resulting Damage 5.5.4 Effect on Operations and Functionality |
144 | 5.5.5 Recovery Actions and Issues |
146 | 5.6 Wastewater Treatment Plants |
147 | 5.6.1 Facility Location and Construction |
148 | 5.6.2 Preparing for Hurricane Sandy 5.6.3 Level of Flooding and Resulting Damage 5.6.4 Effect on Operations and Functionality |
149 | 5.6.5 Recovery Actions and Issues |
151 | 5.7 Transportation Facilities |
152 | 5.7.1 Facility Location and Construction |
153 | 5.7.2 Preparing for Hurricane Sandy |
154 | 5.7.3 Level of Flooding and Resulting Damage 5.7.4 Effect on Operations and Functionality |
156 | 5.7.5 Recovery Actions and Issues |
159 | Chapter 6. Historic Properties |
161 | 6.1 All Saints Episcopal Church (Bay Head, NJ) |
164 | 6.2 Erie-Lackawanna Terminal (Hoboken, NJ) |
165 | 6.3 Monmouth Boat Club (Red Bank, NJ) |
167 | 6.4 Ocean Grove Auditorium (Ocean Grove, NJ) |
168 | 6.5 Statue of Liberty National Monument (New York Harbor) 6.5.1 Ellis Island 6.5.2 Liberty Island |
171 | 6.6 Jacob Riis Park (Queens, NY) |
174 | 6.7 South Street Seaport Historic District (Manhattan, NY) |
177 | Chapter 7. Conclusions and Recommendations 7.1 Summary of Building Performance |
179 | 7.2 General Conclusions and Recommendations |
180 | 7.3 Codes and Standards 7.3.1 New Jersey |
182 | 7.3.2 New York State |
183 | 7.3.3 New York City |
185 | 7.3.4 Healthcare Facility-Specific Standards |
186 | 7.3.5 FEMA |
187 | 7.4 Siting |
189 | 7.5 Structural |
192 | 7.5.1 Flood Protection |
193 | 7.5.2 Elevating Structures and Freeboard |
197 | 7.6 Building Systems 7.6.1 General Protection |
199 | 7.6.2 Elevators |
200 | 7.6.3 Fuel Tanks and Emergency Pumps |
201 | 7.7 Continuity of Operations in Critical Facilities and Other Key Assets |
202 | 7.7.1 Planning for Continuity of Operations |
204 | 7.7.2 Healthcare Facilities |
205 | 7.7.3 Gas Stations 7.7.4 Transit Facilities (Maintenance Facilities, Entry Stations) |
206 | 7.7.5 Wastewater Treatment Plants |
207 | 7.8 Historic |
209 | 7.9 Summary of Conclusions and Recommendations |
217 | References |