{"id":120139,"date":"2024-10-19T04:14:32","date_gmt":"2024-10-19T04:14:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-international-plumbing-code-ipc-2003\/"},"modified":"2024-10-24T22:48:46","modified_gmt":"2024-10-24T22:48:46","slug":"icc-international-plumbing-code-ipc-2003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-international-plumbing-code-ipc-2003\/","title":{"rendered":"ICC International Plumbing Code (IPC) 2003"},"content":{"rendered":"

The code provides comprehensive minimum regulations for plumbing facilities in terms of both performance and prescriptive objectives providing for the acceptance of new and innovative products, materials, and systems.<\/p>\n

<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nPreface <\/td>\n<\/tr>\n
5<\/td>\nOrdinance <\/td>\n<\/tr>\n
7<\/td>\nTable Of Contents <\/td>\n<\/tr>\n
9<\/td>\nChapter 1 – Administration
Section 101 – General
Section 102 – Applicability <\/td>\n<\/tr>\n
10<\/td>\nSection 103 – Department Of Plumbing Inspection
Section 104 – Duties And Powers Of The Code Official
Section 105 – Approval <\/td>\n<\/tr>\n
11<\/td>\nSection 106 – Permits <\/td>\n<\/tr>\n
13<\/td>\nSection 107 – Inspections And Testing <\/td>\n<\/tr>\n
14<\/td>\nSection 108 – Violations
Section 109 – Means Of Appeal <\/td>\n<\/tr>\n
17<\/td>\nChapter 2 – Definitions
Section 201 – General
Section 202 – Defintions <\/td>\n<\/tr>\n
25<\/td>\nChapter 3 – General Regulations
Section 301 – General
Section 302 – Exclusion Of Materials Detrimental To The Sewer System
Section 303 – Materials
Section 304 – Rodent Proofing <\/td>\n<\/tr>\n
26<\/td>\nTable 303.4 – Products And Materials Requiring Third-Party Testing And Third-Party Certification
Section 305 – Protection Of Pipes And Plumbing System Components
Section 306 – Trenching, Excavation And Backfill <\/td>\n<\/tr>\n
27<\/td>\nSection 307 – Structural Safety
Section 308 – Piping Support <\/td>\n<\/tr>\n
28<\/td>\nTable 308.5 – Hanger Spacing
Section 309 – Flood Hazard Resistance
Section 310 – Washroom Toilet Room Requirements <\/td>\n<\/tr>\n
29<\/td>\nSection 311 – Toilet Facilities For Workers
Section 312 – Tests And Inspections <\/td>\n<\/tr>\n
30<\/td>\nSection 313 – Equipment Efficiencies
[M] Section 314 – Condensate Disposal <\/td>\n<\/tr>\n
31<\/td>\nChapter 4 – Fixtures, Faucets And Fixture Fittings
Section 401 – General
Section 402 – Fixture Materials
Section 403 – Minimum Plumbing Facilities
Table 403.1 – Minimum Number Of Required Plumbing Fixtures <\/td>\n<\/tr>\n
32<\/td>\nTable 403.1 – Continued <\/td>\n<\/tr>\n
33<\/td>\nTable 403.1 – Continued <\/td>\n<\/tr>\n
34<\/td>\nSection 404 – Accessible Plumbing Facilities
Section 405 – Installation Of Fixtures <\/td>\n<\/tr>\n
35<\/td>\nFigure 405.3.1 – Fixture Clearance
Section 406 – Automatic Clothes Washers
Section 407 – Bathtubs
Section 408 – Bidets <\/td>\n<\/tr>\n
36<\/td>\nSection 409 – Dishwashing Machines
Section 410 – Drinking Fountains
Section 411 – Emergency Showers And Eyewash Stations
Section 412 – Floor And Trench Drains
Section 413 – Food Waste Grinder Units
Section 414 – Garbage Can Washers
Section 415 – Laundry Trays
Section 416 – Lavatories <\/td>\n<\/tr>\n
37<\/td>\nSection 417 – Showers
Section 418 – Sinks
Section 419 – Urinals <\/td>\n<\/tr>\n
38<\/td>\nSection 420 – Water Closets
Section 421 – Whirlpool Bathtubs
Section 422 – Health Care Fixtures And Equipment <\/td>\n<\/tr>\n
39<\/td>\nSection 423 – Specialty Plumbing Fixtures
Section 424 – Faucets And Other Fixture Fittings
Section 425 – Flushing Devices For Water Closets And Urinals <\/td>\n<\/tr>\n
40<\/td>\nSection 426 – Manual Food And Beverage Dispensing Equipment
Section 427 – Floor Sinks <\/td>\n<\/tr>\n
41<\/td>\nChapter 5 – Water Heaters
Section 501 – General
Section 502 – Installation
Section 503 – Connections
Section 504 – Safety Devices <\/td>\n<\/tr>\n
42<\/td>\nSection 505 – Insulation <\/td>\n<\/tr>\n
43<\/td>\nChapter 6 – Water Supply And Distribution
Section 601 – General
Section 602 – Water Required
Section 603 – Water Service <\/td>\n<\/tr>\n
44<\/td>\nSection 604 – Design Of Building Water Distribution System
Table 604.3 – Water Distribution System Design Criteria Required Capacity At Fixture Supply Pipe Outlets
Table 604.4 – Maximum Flow Rates And Consumption For Plumbing Fixtures And Fixture Fittings <\/td>\n<\/tr>\n
45<\/td>\nTable 604.5 – Minimum Sizes Of Fixture Water Supply Pipes
Table 604.10.1 – Manifold Sizing
Section 605 – Materials, Joints And Connections <\/td>\n<\/tr>\n
46<\/td>\nTable 605.3 – Water Service Pipe
Table 605.4 – Water Distribution Pipe <\/td>\n<\/tr>\n
47<\/td>\nTable 605.5 – Pipe Fittings
Table 605.8 – Manufactured Pipe Nipples <\/td>\n<\/tr>\n
49<\/td>\nSection 606 – Installation Of The Building Water Distribution System <\/td>\n<\/tr>\n
50<\/td>\nTable 606.5.4 – Sizes For Overflow Pipes For Water Supply Tanks <\/td>\n<\/tr>\n
51<\/td>\nTable 606.5.7 – Size OF Drain Pipes For Water Tanks
Section 607 – Hot Water Supply System
Section 608 – Protection Of Potable Water Supply <\/td>\n<\/tr>\n
52<\/td>\nTable 608.1 – Application Of Backflow Preventers <\/td>\n<\/tr>\n
53<\/td>\nTable 608.8.3 – Size Of Pipe Identification <\/td>\n<\/tr>\n
54<\/td>\nTable 608.15.1 – Minimum Required Air Gaps <\/td>\n<\/tr>\n
56<\/td>\nTable 608.17.1 – Distance From Contamination To Private Water Supplies And Pump Suction Lines
Section 609 – Health Care Plumbing
Section 610 – Disinfection Of Potable Water System <\/td>\n<\/tr>\n
57<\/td>\nSection 611 – Drinking Water Treatment Units
Section 612 – Solar Systems
Section 613 – Temperature Control Devices And Valves <\/td>\n<\/tr>\n
59<\/td>\nChapter 7 – Sanitary Drainage
Section 701 – General
Section 702 – Materials
Table 702.1 – Above-Ground Drainage And Vent Types <\/td>\n<\/tr>\n
60<\/td>\nTable 702.2 – Underground Building Drainage And Vent Pipe
Table 702.3 – Building Sewer Pipe <\/td>\n<\/tr>\n
61<\/td>\nTable 702.4 – Pipe Fittings
Section 703 – Building Sewer
Section 704 – Drainage Piping Installation
Table 704.1 – Slope Of Horizontal Drainage Pipe
Section 705 – Joints <\/td>\n<\/tr>\n
64<\/td>\nTable 705.18 – Caulking Ferule Specifications
Table 705.19 – Soldering Bushing Specifications
Section 706 – Connections Between Drainage Piping And Fittings
Table 706.3 – Fittings For Change In Direction
Section 707 – Prohibited Joints And Connections
Section 708 – Cleanouts <\/td>\n<\/tr>\n
65<\/td>\nSection 709 – Fixture Units <\/td>\n<\/tr>\n
66<\/td>\nTable 709.1 – Crainage Fixture Units For Fixtures And Groups <\/td>\n<\/tr>\n
67<\/td>\nTable 709.2 – Drainage Fixture Units For Fixture Drains Or Traps
Section 710 – Drainage System Sizing
Section 711 – Offsets In Drainage Piping In Buildings Of Five Stories Or More
Section 712 – Sumps And Ejectors <\/td>\n<\/tr>\n
68<\/td>\nTable 710.1(1) – Building Drains And Sewers
Table 710.1(2) Horizontal Fixture Branches And Stacks <\/td>\n<\/tr>\n
69<\/td>\nTable 712.4.2 – Minimum Capacity Of Sewer Pump Or Sewer Ejector
Section 713 – Health Care Plumbing <\/td>\n<\/tr>\n
70<\/td>\nTable 713.11.1 – Stack Sizes For Bedpan Steamers And Boiling-Type Sterilizers
Section 714 – Computerized Drainage Design <\/td>\n<\/tr>\n
71<\/td>\nTable 713.11.3 – Stack Sizes For Pressure Sterilizers
Section 715 – Backwater Valves <\/td>\n<\/tr>\n
73<\/td>\nChapter 8 – Indirect\/Special Waste
Section 801 – General
Section 802 – Indirect Wastes <\/td>\n<\/tr>\n
74<\/td>\nSection 803 – Special Wastes
Section 804 – Materials, Joints And Connections <\/td>\n<\/tr>\n
75<\/td>\nChapter 9 – Vents
Section 901 – General
Section 902 – Materials
Section 903 – Vent Stacks And Stack Vents
Section 904 – Vent Terminals <\/td>\n<\/tr>\n
76<\/td>\nSection 905 – Vent Connections And Grades
Section 906 – Fixture Vents
Table 906.1 – Maximum Distance Of Fixture Trap From Vent
Section 907 – Individual Vent
Section 908 – Common Vent
Table 908.3 – Common Vent Sizes
Section 909 – Wet Venting <\/td>\n<\/tr>\n
77<\/td>\nTable 909.3 – Wet Vent Size
Section 910 – Waste Stack Vent
Table 910.4 – Waste Stack Vent Size
Section 911 – Circuit Venting <\/td>\n<\/tr>\n
78<\/td>\nSection 912 – Combination Drain And Vent System
Table 912.3 – Size Of Combination Drain And Vent Pipe
Section 913 – Island Fixture Venting
Section 914 – Relief Vents – Stacks Of More Than 10 Branch Intervals <\/td>\n<\/tr>\n
79<\/td>\nSection 915 – Vents For Stack Offsets
Section 916 – Vent Pipe Sizing
Table 916.1 – Size And Developed Length Of Stack Vents And Vent Stacks <\/td>\n<\/tr>\n
80<\/td>\nTable 916.1 – Continued
Section 917 – Air Admittance Valves <\/td>\n<\/tr>\n
81<\/td>\nTable 916.5.1 – Size And Length Of Sump Vents
Section 918 – Engineered Vent Systems
(Equation 9-1) <\/td>\n<\/tr>\n
82<\/td>\nTable 918.2 – Minimum Diameter And Maximum Length Of Individual Branch Fixture Vents And Individual Fixture Header Vents For Smooth Pipes
Section 919 – Computerized Vent Design <\/td>\n<\/tr>\n
83<\/td>\nChapter 10 – Traps, Interceptors And Separators
Section 1001 – General
Section 1002 – Trap Requirements
Section 1003 – Interceptors And Separators <\/td>\n<\/tr>\n
84<\/td>\nTable 1003.3.4.1 – Capacity Of Grease Traps <\/td>\n<\/tr>\n
85<\/td>\nSection 1004 – Materials, Joints And Connections <\/td>\n<\/tr>\n
87<\/td>\nChapter 11 – Storm Drainage
Section 1101 – General
Section 1102 – Materials
Table 1102.4 – Building Storm Sewer Pipe
Table 1102.5 – Subsoil Drain Pipe <\/td>\n<\/tr>\n
88<\/td>\nTable 1102.7 – Pipe Fittings
Section 1103 – Traps
Section 1104 – Conductors And Connections
Section 1105 – Roof Drains
Section 1106 – Size And Conductors, Leaders And Storm Drains <\/td>\n<\/tr>\n
89<\/td>\nFigure 1106.1 – 100-Year, 1-Hour Rainfall (inches) Eastern United States <\/td>\n<\/tr>\n
90<\/td>\nFigure 1106.1 – Continued 100-Year, 1-Hour Rainfall (inches) Central United States <\/td>\n<\/tr>\n
91<\/td>\nFigure 1106.1 – Continued 100-Year, 1-Hour Rainfall (inches) Western United States <\/td>\n<\/tr>\n
92<\/td>\nFigure 1106.1 – Continued 100-Year, 1-Hour Rainfall (inches) Alaska <\/td>\n<\/tr>\n
93<\/td>\nFigure 1106.1 – Continued 100-Year, 1-Hour Rainfall (inches) Hawaii <\/td>\n<\/tr>\n
94<\/td>\nTable 1106.2 – Size OF Vertical Conductors And Leaders
Table 1106.3 – Size Of Horizontal Storm Drainage Piping <\/td>\n<\/tr>\n
95<\/td>\nTable 1106.6 – Size Of Semicircular Roof Gutters
Section 1107 – Secondary (Emergency) Roof Drains <\/td>\n<\/tr>\n
96<\/td>\nSection 1108 – Combined Sanitary And Storm Sewer
Section 1109 – Values For Continuous Flow
Section 1110 – Controlled Flow roof Drain Systems
Section 1111 – Subsoil Drains
Section 1112 – Building Subdrains
Section 1113 – Sumps And Pumping Systems <\/td>\n<\/tr>\n
97<\/td>\nChapter 12 – Special Piping And Storage Systems
Section 1201 – General
Section 1202 – General
Section 1202 – Medical Gases
Section 1203 – Oxygen Systems <\/td>\n<\/tr>\n
99<\/td>\nChapter 13 – Referenced Standards <\/td>\n<\/tr>\n
107<\/td>\nAppendix A – Plumbing Permit Fee Schedule
Permit Issuance
Unit Fee Schedule
Other Inspection And Fees <\/td>\n<\/tr>\n
109<\/td>\nAppendix B – Rates Of Rainfall For Various Cities <\/td>\n<\/tr>\n
111<\/td>\nAppendix C – Gray Water Recycling Systems
C101 – Gray Water Recycling Systems <\/td>\n<\/tr>\n
113<\/td>\nAppendix D – Degree Day And Design Temperatures
Table D101 – Degree Day And Design Temperatures For Cities In The United States <\/td>\n<\/tr>\n
114<\/td>\nTable D101 – Continued <\/td>\n<\/tr>\n
115<\/td>\nTable D101 – Continued <\/td>\n<\/tr>\n
116<\/td>\nTable D101 – Continued <\/td>\n<\/tr>\n
117<\/td>\nTable D101 – Continued <\/td>\n<\/tr>\n
119<\/td>\nAppendix E – Sizing OF Water Piping System
Section E101 – General
Section E102 – Information Required
Section E103 – Selection Of Pipe Size <\/td>\n<\/tr>\n
124<\/td>\nFigure E103.3(1) – Example Sizing <\/td>\n<\/tr>\n
125<\/td>\nTable E103.3(1) – Recommended Tabular Arrangement For Use In Solving Pipe Sizing Problems <\/td>\n<\/tr>\n
126<\/td>\nTable E103.3(2) – Load Values Assigned To Fixtures <\/td>\n<\/tr>\n
127<\/td>\nTable E103.3(3) – Table For Estimating Demand <\/td>\n<\/tr>\n
128<\/td>\nTable E103.3(4) – Loss Of Pressure Through Taps And Tees In Pounds Per Square Inch (psi)
Table E103.3(5) – Allowance In Equivalent Lengths Of Pipe For Friction Loss In Valves And Threaded Fittings (feet) <\/td>\n<\/tr>\n
129<\/td>\nTable E103.3(6) – Pressure Loss In Fittings And Valves Expressed As Equivalent Length Of Tube (feet) <\/td>\n<\/tr>\n
130<\/td>\nFigure E103.3(2) – Friction Loss In Smooth Pipe (Type K, ASTM B 88 Copper Tubing) <\/td>\n<\/tr>\n
131<\/td>\nFigure E103.3(3) – Friction Loss In Smooth Pipe (Type L, ASTM B 88 Copper Tubing) <\/td>\n<\/tr>\n
132<\/td>\nFigure E103.3(4) – Friction Loss In Smooth Pipe (Type M, ASTM B 88 Copper Tubing) <\/td>\n<\/tr>\n
133<\/td>\nFigure E103.3(5) – Friction Lpss In Fairly Smooth Pipe <\/td>\n<\/tr>\n
134<\/td>\nFigure E103.3(6) – Friction Loss In Fairly Rough Pipe <\/td>\n<\/tr>\n
135<\/td>\nFigure E103.3(7) – Friction Loss In Fairly Rough Pipe <\/td>\n<\/tr>\n
136<\/td>\nSection E201 – Selection Of Pipe Size <\/td>\n<\/tr>\n
137<\/td>\nTable E201.1 – Minimum Size Of Water Meters, Mains And Distribution Piping Based On Water Supply Fixture Unit Values <\/td>\n<\/tr>\n
138<\/td>\nTable E201.1 – Continued <\/td>\n<\/tr>\n
139<\/td>\nAppendix F – Structural Safety
Section F101 – Cutting, Notching And Boring In Wood Members <\/td>\n<\/tr>\n
141<\/td>\nAppendix G – Vacuum Drainage System
Section G101 – Vacuum Drainage System <\/td>\n<\/tr>\n
143<\/td>\nIndex <\/td>\n<\/tr>\n
151<\/td>\nEditorial Changes – Second Printing <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

International Plumbing Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2003<\/td>\n152<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":120140,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-120139","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/120139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/120140"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=120139"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=120139"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=120139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}