{"id":211801,"date":"2024-10-19T13:42:16","date_gmt":"2024-10-19T13:42:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1052-2018\/"},"modified":"2024-10-25T06:30:55","modified_gmt":"2024-10-25T06:30:55","slug":"ieee-1052-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1052-2018\/","title":{"rendered":"IEEE 1052 2018"},"content":{"rendered":"

New IEEE Standard – Active. Assisting users in specifying the functional requirements for transmission static synchronous compensator (STATCOM) systems using forced commutated technology based on voltage sourced converter topologies is the purpose of this guide. These systems may be hybrid,and also incorporate thyristor and mechanically switched inductors and capacitors. Reactive power compensation, voltage regulation and control, transient and dynamic stability, and control and protection are the functions included. Accepted engineering practices for the application of STATCOM systems are presented. Specifications, typical application requirements, engineering studies, main component characteristics, system functions and features, factory testing, commissioning, and operations are covered. Informative annexes that allow users to develop or modify specific clauses to meet the requirements of a particular transmission system application are included.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1052\u2122-2018 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
9<\/td>\nIntroduction <\/td>\n<\/tr>\n
10<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\n1.\u2002Overview
1.1\u2002Scope
1.2\u2002Purpose <\/td>\n<\/tr>\n
13<\/td>\n1.3\u2002Application
2.\u2002Normative references <\/td>\n<\/tr>\n
14<\/td>\n3.\u2002Definitions, acronyms and abbreviations
3.1\u2002Definitions <\/td>\n<\/tr>\n
15<\/td>\n3.2\u2002Acronyms and abbreviations <\/td>\n<\/tr>\n
17<\/td>\n4.\u2002STATCOM system project description <\/td>\n<\/tr>\n
18<\/td>\n5.\u2002Scope of supply and schedule
5.1\u2002Scope of supply <\/td>\n<\/tr>\n
20<\/td>\n5.2\u2002Schedule
6.\u2002Site and environmental data <\/td>\n<\/tr>\n
21<\/td>\n7.\u2002Power system characteristics <\/td>\n<\/tr>\n
22<\/td>\n8.\u2002STATCOM system characteristics
8.1\u2002STATCOM system rating <\/td>\n<\/tr>\n
25<\/td>\n8.2\u2002Control objectives <\/td>\n<\/tr>\n
29<\/td>\n8.3\u2002Harmonic performance <\/td>\n<\/tr>\n
30<\/td>\n8.4\u2002Telephone and radio interference
8.5\u2002Audible noise
8.6\u2002Loss evaluation <\/td>\n<\/tr>\n
32<\/td>\n8.7\u2002STATCOM system availability and reliability <\/td>\n<\/tr>\n
33<\/td>\n9.\u2002Main components\u2014required functions and features
9.1\u2002General requirement
9.2\u2002Switching devices [VSC (STATCOM) and thyristor valves (TSC\/TSR)] <\/td>\n<\/tr>\n
35<\/td>\n9.3\u2002VSC (STATCOM) and thyristor valves (TSC\/TSR) cooling system <\/td>\n<\/tr>\n
36<\/td>\n9.4\u2002Control equipment and operator interface <\/td>\n<\/tr>\n
37<\/td>\n9.5\u2002Monitoring and protection <\/td>\n<\/tr>\n
39<\/td>\n9.6\u2002Reactors and phase reactors <\/td>\n<\/tr>\n
40<\/td>\n9.7\u2002Capacitors and ac filters
9.8\u2002Power transformers
9.9\u2002Switchgear
9.10\u2002Auxiliary power supplies
10.\u2002Spares
10.1\u2002Spares strategy <\/td>\n<\/tr>\n
41<\/td>\n10.2\u2002Spare parts storage
10.3\u2002Spare parts accounting <\/td>\n<\/tr>\n
42<\/td>\n11.\u2002Engineering studies
11.1\u2002Information submitted with bid
11.2\u2002Pre-manufacturing engineering and design verification studies <\/td>\n<\/tr>\n
44<\/td>\n11.3\u2002Post-commissioning studies
12.\u2002Tests
12.1\u2002Factory tests of switching devices <\/td>\n<\/tr>\n
45<\/td>\n12.2\u2002Factory tests of controls <\/td>\n<\/tr>\n
46<\/td>\n12.3\u2002Tests of other components
12.4\u2002Field tests
13.\u2002Documentation
14.\u2002Training <\/td>\n<\/tr>\n
47<\/td>\n15.\u2002Balance of plant
15.1\u2002Buildings and structures
15.2\u2002Fire protection <\/td>\n<\/tr>\n
48<\/td>\n15.3\u2002Site requirements and conditions <\/td>\n<\/tr>\n
49<\/td>\nAnnex\u00a0A (informative) Bibliography <\/td>\n<\/tr>\n
53<\/td>\nAnnex\u00a0B (informative) Notes for a functional specification
B.1\u2002STATCOM system project description (refer to Clause\u00a04) <\/td>\n<\/tr>\n
55<\/td>\nB.2\u2002Scope of supply and schedule (refer to Clause\u00a05) <\/td>\n<\/tr>\n
56<\/td>\nB.3\u2002Site and environmental data (refer to Clause\u00a06)
B.4\u2002Power system characteristics (refer to Clause\u00a07) <\/td>\n<\/tr>\n
58<\/td>\nB.5\u2002Main STATCOM system characteristics (refer to Clause\u00a08) <\/td>\n<\/tr>\n
86<\/td>\nB.6\u2002Main components\u2014required functions and features (refer to Clause\u00a09) <\/td>\n<\/tr>\n
95<\/td>\nB.7\u2002Spares (refer to Clause\u00a010) <\/td>\n<\/tr>\n
96<\/td>\nB.8\u2002Engineering studies (refer to Clause\u00a011) <\/td>\n<\/tr>\n
99<\/td>\nB.9\u2002Tests (refer to Clause\u00a012) <\/td>\n<\/tr>\n
100<\/td>\nB.10\u2002Documentation (refer to Clause\u00a013) <\/td>\n<\/tr>\n
101<\/td>\nB.11\u2002Training (refer to Clause\u00a014)
B.12\u2002Balance of plant (refer to Clause\u00a015) <\/td>\n<\/tr>\n
104<\/td>\nAnnex\u00a0C (informative) Method of calculating VSC losses <\/td>\n<\/tr>\n
105<\/td>\nAnnex\u00a0D (informative) Geomagnetic induced current
D.1\u2002GIC description
D.2\u2002GIC impact on SVC and STATCOM system design and operation <\/td>\n<\/tr>\n
106<\/td>\nD.3\u2002Performance under GIC conditions
D.4\u2002Example of GIC specification <\/td>\n<\/tr>\n
108<\/td>\nAnnex\u00a0E (informative) Phase angle jump – occurrence and mitigation
E.1\u2002Design consideration
E.2\u2002Mechanisms
E.3\u2002Consequences on the operation of the STATCOM <\/td>\n<\/tr>\n
110<\/td>\nAnnex\u00a0F (informative) Discussion on auxiliary power supply
F.1\u2002STATCOM system auxiliary supply \u2013 options and specification considerations <\/td>\n<\/tr>\n
113<\/td>\nF.2\u2002Auxiliary supply power quality <\/td>\n<\/tr>\n
115<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Guide for Specification of Transmission Static Synchronous Compensator (STATCOM) Systems<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2019<\/td>\n115<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":211805,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-211801","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/211801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/211805"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=211801"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=211801"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=211801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}