{"id":233277,"date":"2024-10-19T15:12:13","date_gmt":"2024-10-19T15:12:13","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61988-2-12012\/"},"modified":"2024-10-25T09:41:17","modified_gmt":"2024-10-25T09:41:17","slug":"bs-en-61988-2-12012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61988-2-12012\/","title":{"rendered":"BS EN 61988-2-1:2012"},"content":{"rendered":"
IEC 61988-2-1:2012 determines the following measuring methods for characterizing the performance of plasma display modules (PDP modules): a) four per cent (4 %) window luminance; b) luminance uniformity; c) dark-room contrast ratio; d) bright-room contrast ratio 100\/70; e) white chromaticity and chromatic uniformity; f) colour gamut in the centre box; g) module power and current consumption; h) module power consumption using video signal; i) module luminous efficacy, and j) panel luminous efficacy. This edition includes the following significant technical changes with respect to the previous edition: The first edition of IEC 61988-2-1 and IEC 61988-2-2 were combined and reconstructed in this document.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4 Structure of measuring equipment 5 Standard measuring conditions 5.1 Environmental conditions 5.2 Set-up conditions 5.2.1 General <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.2.2 Measuring layout 5.2.3 Field frequency Figures Figure 1 \u2013 Measuring layout (side view) <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5.2.4 Adjustment of PDP modules 5.2.5 Warm-up condition of PDP modules 5.3 Lighting conditions 5.3.1 Dark-room conditions 5.3.2 Bright-room conditions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 2 \u2013 Example of bright-room conditions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6 Measuring methods 6.1 Measuring methods of 4\u00a0% window luminance 6.1.1 Purpose 6.1.2 Measuring equipment 6.1.3 Measurement Figure 3 \u2013 Four per cent (4 %) window luminance measuring pattern <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.2 Measuring method of luminance uniformity 6.2.1 Purpose 6.2.2 Measuring equipment 6.2.3 Measurement <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.3 Measuring method of dark-room contrast ratio 6.3.1 Purpose 6.3.2 Measuring equipment Figure 4 \u2013 Measuring points Tables Table 1 \u2013 Example of luminance uniformity measurement <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.3.3 Measurement <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.4 Measuring method of bright-room contrast ratio 100\/70 6.4.1 General 6.4.2 Purpose 6.4.3 Measuring equipment 6.4.4 Measurement Figure 5 \u2013 Minimum luminance measuring pattern <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.5 Measuring method of white chromaticity and chromatic uniformity 6.5.1 Purpose 6.5.2 Measuring equipment 6.5.3 Measurement <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.6 Measuring method of colour gamut 6.6.1 Purpose 6.6.2 Measuring equipment 6.6.3 Measurement Table 2 \u2013 Example of chromaticity measurement <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.7 Measuring method of module power and current consumption 6.7.1 Purpose 6.7.2 Measuring equipment Figure 6 \u2013 Example of the colour gamut measurement <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.7.3 Measurement Figure 7 \u2013 Example of power and current measuring diagram <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 3 \u2013 Example of power and current measurements (for a module that includes an AC input) Table 4 \u2013 Example of power and current measurement (for a module with DC inputs only) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.8 Measuring method of module power consumption using video signal 6.8.1 General 6.8.2 Measuring equipment 6.8.3 Applied digital video signal 6.8.4 Image processing board <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.8.5 Measurement Table 5 \u2013 Example of measurement results of module power consumption using video signal <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.9 Measuring method of module luminous efficacy 6.9.1 Purpose 6.9.2 Measuring equipment 6.9.3 Measurement <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.10 Measuring method of panel luminous efficacy 6.10.1 Purpose 6.10.2 Measuring equipment <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.10.3 Panel conditions Figure 8 \u2013 System diagram of sustain power measurement <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.10.4 Driving waveform <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.10.5 Applied display patterns 6.10.6 Measurement Figure 9 \u2013 Driving system and waveform <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex A (informative) Clause cross-references from the previous edition of IEC 61988-2-1:2002 and IEC 61988-2-2:2003 to IEC 61988-2-1:2011 <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Table A.1 \u2013 Clause cross-references <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Plasma display panels – Measuring methods. Optical and optoelectrical<\/b><\/p>\n |