{"id":28227,"date":"2024-10-17T02:57:37","date_gmt":"2024-10-17T02:57:37","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-286-11\/"},"modified":"2024-10-24T14:01:39","modified_gmt":"2024-10-24T14:01:39","slug":"nfpa-286-11","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-286-11\/","title":{"rendered":"NFPA 286 11"},"content":{"rendered":"

The 2011 NFPA 286’s broader scope helps you accurately assess fire growth impact of all types wall and ceiling interior finishes. NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth provides a method of determining the flammability characteristics of exterior, non-load bearing wall assemblies and panels which are required to be of non-combustible construction but may contain combustible components. In the 2011 edition, the scope was expanded and rules were added to cover all wall coverings, including textile wall coverings. Order your copy of NFPA 286 today and give people the data they need to make informed, fire-smart decisions when selecting wall and ceiling interior finish materials.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
3<\/td>\nAdditional Notices and Disclaimers <\/td>\n<\/tr>\n
4<\/td>\n2.1 General
2.2 NFPA Publications. (Reserved) <\/td>\n<\/tr>\n
7<\/td>\nChapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Application <\/td>\n<\/tr>\n
8<\/td>\nChapter 2 Referenced Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
Chapter 4 Test Equipment
4.1 Ignition Source <\/td>\n<\/tr>\n
9<\/td>\n4.2 Geometry and Construction of the Fire Test Room
Chapter 5 Specimen Mounting
5.1 Specimen Mounting <\/td>\n<\/tr>\n
10<\/td>\n5.2 Materials Using Substrates
5.3 Backing Materials
5.4 Acoustical Materials and Other Board Materials <\/td>\n<\/tr>\n
11<\/td>\n5.5 Batt- or Blanket-Type Insulating and Other Flexible Materials
5.6 Building Units
5.7 Site-Fabricated Stretch Systems <\/td>\n<\/tr>\n
12<\/td>\n5.8 Wall or Ceiling Covering Materials
5.9 Ceiling Lining Materials
5.10 Specimen Installation
5.11 Conditioning <\/td>\n<\/tr>\n
13<\/td>\nChapter 6 Environmental Conditions
6.1 Fire Test Room Environment
Chapter 7 Instrumentation
7.1 Fire Test Room Instrumentation <\/td>\n<\/tr>\n
14<\/td>\n7.2 Canopy Hood and Exhaust Duct
7.3 Instrumentation in Exhaust Duct <\/td>\n<\/tr>\n
18<\/td>\nChapter 8 Calibration
8.1 Calibration and Documentation of Ignition Source and Test Equipment
8.2 Calibration Procedure <\/td>\n<\/tr>\n
19<\/td>\n8.3 Smoke Measurement Calibration
8.4 Gas Analyzers Calibration
Chapter 9 Test Procedure
9.1 Procedure
Chapter 10 Calculation Methods
10.1 Mass Flow Rate
10.2 Smoke Measurement Equations
10.3 Release Rate of Combustion Gases <\/td>\n<\/tr>\n
20<\/td>\n10.4 Symbols
Chapter 11 Report
11.1 Report <\/td>\n<\/tr>\n
21<\/td>\n11.2 Discussion of Performance
Annex A Explanatory Material <\/td>\n<\/tr>\n
23<\/td>\nAnnex B Method of Determining Suitability of Oxygen Analyzers for Making Heat Release Measurements <\/td>\n<\/tr>\n
24<\/td>\nAnnex C Acceptance Criteria
Annex D Informational References <\/td>\n<\/tr>\n
26<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2011<\/td>\n29<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":28228,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-28227","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/28227","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/28228"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=28227"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=28227"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=28227"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}