{"id":305034,"date":"2024-10-19T20:52:09","date_gmt":"2024-10-19T20:52:09","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-14072011\/"},"modified":"2024-10-25T18:26:28","modified_gmt":"2024-10-25T18:26:28","slug":"bs-iso-14072011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-14072011\/","title":{"rendered":"BS ISO 1407:2011"},"content":{"rendered":"

This International Standard specifies four methods for the quantitative determination of the material extractable from raw rubbers, both natural and synthetic; two of the methods are also applicable to the unvulcanized and vulcanized compounds of raw rubbers.<\/p>\n

Method A measures the mass of the solvent extract, after evaporation of the solvent, relative to the mass of the original test portion.<\/p>\n

Method B measures the difference in the mass of the test portion before and after extraction.<\/p>\n

Method C, which is for raw rubbers only, measures the difference in the mass of the test portion before and after extraction using boiling solvent.<\/p>\n

Method D, which is for raw rubbers only, measures the difference in the mass of the test portion before and after extraction relative to the mass of the original test portion.<\/p>\n

\n

NOTE 1 Depending on the test method used, the conditioning of the test portion and the solvent used, the test result is not necessarily the same.<\/p>\n<\/blockquote>\n

\n

NOTE 2 Method C generally gives results which are lower than those obtained with methods A and B due to the fact that an equilibrium is set up, particularly if large test portions are used, depending on the content and the nature of the extractable matter. Method C is, however, a quicker method than method A or method B.<\/p>\n<\/blockquote>\n

\n

NOTE 3 Methods C and D are not suitable if the test portion disintegrates during the extraction.<\/p>\n<\/blockquote>\n

\n

NOTE 4 Method D is normally used for production controls.<\/p>\n<\/blockquote>\n

Recommendations as to the solvent most appropriate for each type of rubber are given in Annex A.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\n1\tScope
2\tNormative references
3\tPrinciple <\/td>\n<\/tr>\n
8<\/td>\n4\tSolvent
5\tApparatus
6\tPreparation of test pieces
6.1\tMethods\u00a0A and\u00a0B
6.2\tMethod\u00a0C (raw rubbers only) <\/td>\n<\/tr>\n
10<\/td>\n6.3\tMethod\u00a0D (raw rubbers only)
7\tProcedure
7.1\tGeneral
7.2\tMethod\u00a0A
7.3\tMethod\u00a0B <\/td>\n<\/tr>\n
11<\/td>\n7.4\tMethod\u00a0C <\/td>\n<\/tr>\n
12<\/td>\n7.5\tMethod\u00a0D <\/td>\n<\/tr>\n
13<\/td>\n8\tCalculation and expression of results
8.1\tMethod\u00a0A
8.2\tMethod\u00a0B <\/td>\n<\/tr>\n
14<\/td>\n8.3\tMethod\u00a0C
8.4\tMethod\u00a0D
8.5\tExpression of results
9\tPrecision
10\tTest report <\/td>\n<\/tr>\n
16<\/td>\nAnnex\u00a0A
\n(informative)<\/p>\n

Recommended solvents <\/td>\n<\/tr>\n

18<\/td>\nAnnex\u00a0B
\n(informative)<\/p>\n

Precision <\/td>\n<\/tr>\n

22<\/td>\nAnnex\u00a0C
\n(informative)<\/p>\n

Example of determination of minimum number of extraction cycles for a raw rubber plus solvent combination of EPDM and 2-butanone <\/td>\n<\/tr>\n

23<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Rubber. Determination of solvent extract<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2011<\/td>\n26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":305036,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-305034","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/305034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/305036"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=305034"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=305034"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=305034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}