{"id":344352,"date":"2024-10-20T00:11:03","date_gmt":"2024-10-20T00:11:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-84182015a12017\/"},"modified":"2024-10-25T23:33:00","modified_gmt":"2024-10-25T23:33:00","slug":"bs-84182015a12017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-84182015a12017\/","title":{"rendered":"BS 8418:2015+A1:2017"},"content":{"rendered":"

This British Standard gives recommendations for the design, installation, commissioning, maintenance, operation and remote monitoring of detector-activated CCTV systems, whether “permanent” or temporary\/portable.<\/p>\n

This standard applies irrespective of the length of time the CCTV systems are installed and\/or whether the equipment can be re-used on another site.<\/p>\n

This standard is intended to provide recommendations to the following parties:<\/p>\n

    \n
  1. \n

    CCTV companies, on best practice for the design, installation, commissioning, maintenance and operation of detector-activated CCTV systems;<\/p>\n

    \n

    NOTE This includes the installation and maintenance engineers working for the CCTV company.<\/p>\n<\/blockquote>\n<\/li>\n

  2. \n

    Remote video response centres (RVRCs) monitoring CCTV systems; and<\/p>\n<\/li>\n

  3. \n

    customers regarding the management of CCTV systems.<\/p>\n<\/li>\n<\/ol>\n

    PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
    PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
    4<\/td>\nForeword <\/td>\n<\/tr>\n
    7<\/td>\nIntroduction
    1 Scope
    2 Normative references <\/td>\n<\/tr>\n
    8<\/td>\n3 Terms, definitions and abbreviations <\/td>\n<\/tr>\n
    11<\/td>\n4 CCTV system planning and design <\/td>\n<\/tr>\n
    17<\/td>\nTable 1 \u2014 Tamper detection and indication
    Table 2 \u2014 Fault recognition and indication <\/td>\n<\/tr>\n
    21<\/td>\n5 Installation <\/td>\n<\/tr>\n
    22<\/td>\n6 Commissioning <\/td>\n<\/tr>\n
    24<\/td>\n7 Setting\/unsetting procedures of the remotely monitored CCTV systemText deleted <\/td>\n<\/tr>\n
    27<\/td>\n8 Responsibilities and considerations <\/td>\n<\/tr>\n
    28<\/td>\n9 RVRC operator procedures <\/td>\n<\/tr>\n
    29<\/td>\n10 Management and operation of the RVRC <\/td>\n<\/tr>\n
    30<\/td>\n11 RVRC procedures and documentation <\/td>\n<\/tr>\n
    32<\/td>\n12 Activation management
    13 Service levels
    14 General maintenance and personnel screening <\/td>\n<\/tr>\n
    34<\/td>\nAnnex A (informative)\u2002 Diagrams for positioning detectors
    Figure A.1 \u2014 Alignment of long range and wide angle detectors <\/td>\n<\/tr>\n
    35<\/td>\nFigure A.2 \u2014 Correctly positioned detectors near a supervised premises boundary <\/td>\n<\/tr>\n
    36<\/td>\nFigure A.3 \u2014 An incorrectly adjusted detector facing an entrance gate, where the detection exceeds the secure area <\/td>\n<\/tr>\n
    37<\/td>\nFigure A.4 \u2014 An incorrectly positioned detector providing a detection area outside the field of view of the camera
    Figure A.5 \u2014 Example of multiple cameras positioned to view the total detection area
    Annex B (informative)\u2002 Factors affecting the design requirements for a detector-activated CCTV system <\/td>\n<\/tr>\n
    39<\/td>\nAnnex C (informative)\u2002 Types of technology used in detection equipment <\/td>\n<\/tr>\n
    41<\/td>\nAnnex D (informative)\u2002 Illumination of the field of view of the camera
    Figure D.1 \u2014 Correct artificial illumination of the field of view of a camera
    Annex E (normative)\u2002 Checklist criteria for the commissioning of a detector-activated CCTV system
    Table E.1 \u2014 Template for the commissioning of a CCTV system <\/td>\n<\/tr>\n
    43<\/td>\nAnnex F (informative)\u2002 Setting procedure with a detector in the active state <\/td>\n<\/tr>\n
    44<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

    Installation and remote monitoring of detector-activated CCTV systems. Code of practice<\/b><\/p>\n\n\n\n\n
    Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
    BSI<\/b><\/a><\/td>\n2017<\/td>\n46<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":344356,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-344352","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/344352","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/344356"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=344352"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=344352"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=344352"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}