{"id":344352,"date":"2024-10-20T00:11:03","date_gmt":"2024-10-20T00:11:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-84182015a12017\/"},"modified":"2024-10-25T23:33:00","modified_gmt":"2024-10-25T23:33:00","slug":"bs-84182015a12017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-84182015a12017\/","title":{"rendered":"BS 8418:2015+A1:2017"},"content":{"rendered":"
This British Standard gives recommendations for the design, installation, commissioning, maintenance, operation and remote monitoring of detector-activated CCTV systems, whether “permanent” or temporary\/portable.<\/p>\n
This standard applies irrespective of the length of time the CCTV systems are installed and\/or whether the equipment can be re-used on another site.<\/p>\n
This standard is intended to provide recommendations to the following parties:<\/p>\n
CCTV companies, on best practice for the design, installation, commissioning, maintenance and operation of detector-activated CCTV systems;<\/p>\n
\nNOTE This includes the installation and maintenance engineers working for the CCTV company.<\/p>\n<\/blockquote>\n<\/li>\n
- \n
Remote video response centres (RVRCs) monitoring CCTV systems; and<\/p>\n<\/li>\n
- \n
customers regarding the management of CCTV systems.<\/p>\n<\/li>\n<\/ol>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n Foreword <\/td>\n<\/tr>\n \n 7<\/td>\n Introduction
1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 8<\/td>\n 3 Terms, definitions and abbreviations <\/td>\n<\/tr>\n \n 11<\/td>\n 4 CCTV system planning and design <\/td>\n<\/tr>\n \n 17<\/td>\n Table 1 \u2014 Tamper detection and indication
Table 2 \u2014 Fault recognition and indication <\/td>\n<\/tr>\n\n 21<\/td>\n 5 Installation <\/td>\n<\/tr>\n \n 22<\/td>\n 6 Commissioning <\/td>\n<\/tr>\n \n 24<\/td>\n 7 Setting\/unsetting procedures of the remotely monitored CCTV systemText deleted <\/td>\n<\/tr>\n \n 27<\/td>\n 8 Responsibilities and considerations <\/td>\n<\/tr>\n \n 28<\/td>\n 9 RVRC operator procedures <\/td>\n<\/tr>\n \n 29<\/td>\n 10 Management and operation of the RVRC <\/td>\n<\/tr>\n \n 30<\/td>\n 11 RVRC procedures and documentation <\/td>\n<\/tr>\n \n 32<\/td>\n 12 Activation management
13 Service levels
14 General maintenance and personnel screening <\/td>\n<\/tr>\n\n 34<\/td>\n Annex A (informative)\u2002 Diagrams for positioning detectors
Figure A.1 \u2014 Alignment of long range and wide angle detectors <\/td>\n<\/tr>\n\n 35<\/td>\n Figure A.2 \u2014 Correctly positioned detectors near a supervised premises boundary <\/td>\n<\/tr>\n \n 36<\/td>\n Figure A.3 \u2014 An incorrectly adjusted detector facing an entrance gate, where the detection exceeds the secure area <\/td>\n<\/tr>\n \n 37<\/td>\n Figure A.4 \u2014 An incorrectly positioned detector providing a detection area outside the field of view of the camera
Figure A.5 \u2014 Example of multiple cameras positioned to view the total detection area
Annex B (informative)\u2002 Factors affecting the design requirements for a detector-activated CCTV system <\/td>\n<\/tr>\n\n 39<\/td>\n Annex C (informative)\u2002 Types of technology used in detection equipment <\/td>\n<\/tr>\n \n 41<\/td>\n Annex D (informative)\u2002 Illumination of the field of view of the camera
Figure D.1 \u2014 Correct artificial illumination of the field of view of a camera
Annex E (normative)\u2002 Checklist criteria for the commissioning of a detector-activated CCTV system
Table E.1 \u2014 Template for the commissioning of a CCTV system <\/td>\n<\/tr>\n\n 43<\/td>\n Annex F (informative)\u2002 Setting procedure with a detector in the active state <\/td>\n<\/tr>\n \n 44<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Installation and remote monitoring of detector-activated CCTV systems. Code of practice<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2017<\/td>\n 46<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":344356,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-344352","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/344352","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/344356"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=344352"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=344352"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=344352"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}