{"id":401443,"date":"2024-10-20T04:56:22","date_gmt":"2024-10-20T04:56:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-8655-82022\/"},"modified":"2024-10-26T08:44:16","modified_gmt":"2024-10-26T08:44:16","slug":"bs-en-iso-8655-82022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-8655-82022\/","title":{"rendered":"BS EN ISO 8655-8:2022"},"content":{"rendered":"
This document specifies the photometric reference measurement procedure for the determination of volume of piston-operated volumetric apparatus (POVA). The procedure is applicable to complete systems comprising the basic apparatus with a maximum nominal volume of 5 000 \u00b5l and all parts selected for use with the apparatus, disposable or reusable, involved in the measurement by delivery (Ex).<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 General requirements 5 Test equipment 5.1 General 5.2 Spectrophotometer 5.3 Cuvette and mixer <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5.4 Measuring devices 5.5 Equipment used for solution preparation 5.6 Balances <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.7 Density meter 5.8 pH meter 6 Reagents 6.1 General requirements 6.2 Water 6.3 Buffer solution 6.4 Copper(II) chloride solution 6.5 Ponceau S solutions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6.6 Calibrator solutions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.7 Stability of solutions 6.7.1 General 6.7.2 Preservatives 6.7.3 Light sensitivity 6.7.4 Storage temperature 7 Test conditions 7.1 General 7.2 Test room <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 7.3 Evaporation 8 Procedure 8.1 General 8.1.1 Summary 8.1.2 Test conditions 8.1.3 Test volume 8.1.4 Number of measurements per volume to be tested <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 8.2 System calibration 8.2.1 General 8.2.2 System calibration procedure 8.2.3 Previous calibration 8.3 Photometric procedure 8.3.1 Preparation of cuvettes 8.3.2 Zero of the spectrophotometer 8.3.3 Starting absorbances <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 8.3.4 Dispensing of test liquids 8.3.5 Absorbance of the chromophore mixture 8.3.6 Calculation of the delivered test volume 8.4 Preparation 8.5 Single-channel air displacement pipettes (in accordance with ISO 8655\u20112) 8.5.1 General <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 8.5.2 Test cycle <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8.6 Multi-channel pipettes (in accordance with ISO 8655\u20112) 8.7 Positive displacement pipettes (in accordance with ISO 8655\u20112) 8.8 Burettes (in accordance with ISO 8655\u20113) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.9 Dispensers (in accordance with ISO 8655\u20115) 8.10 Syringes (in accordance with ISO 8655\u20119) 8.10.1 General 8.10.2 Test cycle <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 9 Evaluation 9.1 Calculation of volume 9.1.1 Calibration constant 9.1.2 Volume of test liquid 9.1.3 Temperature correction <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.1.4 Mean volume 9.2 Systematic error of measurement 9.3 Random error of measurement <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.4 Uncertainty of measurement 10 Reporting of results <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex A (normative) Calculation of volumes from balance readings <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Piston-operated volumetric apparatus – Photometric reference measurement procedure for the determination of volume<\/b><\/p>\n |