{"id":70433,"date":"2024-10-17T14:21:32","date_gmt":"2024-10-17T14:21:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d76-2011\/"},"modified":"2024-10-24T18:51:13","modified_gmt":"2024-10-24T18:51:13","slug":"astm-d76-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d76-2011\/","title":{"rendered":"ASTM-D76 2011"},"content":{"rendered":"<\/p>\n

1.1 This specification covers the operating characteristics of three types of tensile testing machines used for the determination of the force-elongation properties of textile materials. These types of tensile testing machines are:<\/p>\n

1.1.1 Constant-rate-of-extension, CRE.<\/p>\n

1.1.2 Constant-rate-of-traverse, CRT.<\/p>\n

1.1.3 Constant-rate-of-loading (force), CRL.<\/p>\n

1.2 Specifications for tensile testing machines to measure other tensile-related properties of textile materials not covered by this standard are given in the ASTM standards using those machines.<\/p>\n

1.3 The values stated in SI units are to be regarded as standard; the values in inch-pound units are provided as information only and are not exact equivalents.<\/p>\n

1.4 The following safety hazards caveat pertains only to the test methods described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Performance Requirements <\/td>\n<\/tr>\n
2<\/td>\nApparatus
Machine Operational Design <\/td>\n<\/tr>\n
3<\/td>\nTolerance on Indicated Force, Recorded Elongation, Nominal Gauge Length, and Speed of Moving Clamp
Verification of Indicated Force
FIG. 1 <\/td>\n<\/tr>\n
4<\/td>\nVerification of Recorded Clamp Displacement of CRE-Type Machines
Verification of Recorded Elongation for CRT- and CRL-Type Machines
Verification of Nominal Gauge Length <\/td>\n<\/tr>\n
5<\/td>\nKeywords
A1. FORCE CALIBRATION OF CRL-TYPE MACHINES, INCLINED PLANE TYPE
A1.1
A1.2 <\/td>\n<\/tr>\n
6<\/td>\nA1.3
FIG. A1.1 <\/td>\n<\/tr>\n
7<\/td>\nA2. CAUSES OF ERROR IN RECORDING ELONGATION
A2.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D76\/D76M-11 Standard Specification for Tensile Testing Machines for Textiles<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":70434,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[880,2637],"product_tag":[],"class_list":{"0":"post-70433","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-59-080-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/70433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/70434"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=70433"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=70433"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=70433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}