{"id":72942,"date":"2024-10-17T16:26:08","date_gmt":"2024-10-17T16:26:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-c905-2010\/"},"modified":"2024-10-24T19:08:34","modified_gmt":"2024-10-24T19:08:34","slug":"awwa-c905-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-c905-2010\/","title":{"rendered":"AWWA C905 2010"},"content":{"rendered":"
Pipe manufactured to this standard is generally well suited for conveying potable water, reclaimed water, irrigation water, wastewater, or any fluid compatible with non-plasticized PVC. The standard includes eight dimension ratio (DRs) and nominal pipe sizes ranging from 14 in. through 48 in. (350 mm through 1,200 mm). Pipe outside diameters (ODs) conform to those established for CI-equivalent ODs (CIOD) and steel-pipe-equivalent ODs (IPS). Pressure classes range from 80 psi (550 kPa) to 305 psi (2,100 kPa).<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | ANSI\/AWWA C905-10 \n <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Committee Personnel <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword I. Introduction. <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | II. Special Issues. III. Use of This Standard. <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | IV. Major Revisions. <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | V. Comments. <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | AWWA Standard Polyvinyl Chloride (PVC) Pressure \nPipe and Fabricated Fittings, 14 In. \nThrough 48 In. (350 mm Through \n1,200 mm) \n SECTION 1: GENERAL Sec. 1.1 Scope Sec. 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Sec. 1.3 Application SECTION 2: REFERENCES <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | SECTION 3: DEFINITIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | SECTION 4: REQUIREMENTS Sec. 4.1 Permeation Sec. 4.2 Materials <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Sec. 4.3 Pipe Requirements <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 1-A Dimensions, pressure classes, and dimension ratios for PVC pipe with IPS outside \ndiameter <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside \ndiameter (continued) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 1-B Dimensions, pressure classes, and dimension ratios for PVC pipe with CI outside \ndiameter (continued) <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 2 Pressure-test requirements <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Table 3 Temperature coefficients, F Sec. 4.4 Machined Coupling Requirements <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Sec. 4.5 Fabricated Fitting Requirements <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Sec. 4.6 Joint Requirements Sec. 4.7 Pressure Rating Designations <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table 4 Allowable maximum occasional surge pressure capacity and allowable sudden \nchanges in water velocity for pipe operating at 73\u00b0F at working pressures expressed as percent \nof nominal pressure class (PC) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | SECTION 5: VERIFICATION Sec. 5.1 Quality-Control and Qualification Test Requirements <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Sec. 5.2 Quality Control Records <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Sec. 5.3 Plant Inspection SECTION 6: DELIVERY Sec. 6.1 Marking <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Sec. 6.2 Shipping and Delivery Sec. 6.3 Notice of Nonconformance Sec. 6.4 Affidavit of Compliance <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | APPENDIX A Bibliography \n <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | APPENDIX B Recurring (Cyclic) Surge-Figures and Design Example \n SECTION B.1: DISCUSSION SECTION B.2: DESIGN EXAMPLE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" AWWA C905-10: Polyvinyl Chloride (PVC) Pressure Pipe & Fabricated Fittings, 14 In Thru 48 In (350 MM Thru 1,200 MM) For Water Transmission And Distribution<\/b><\/p>\n |